User manual
Publication 2092-UM001D-EN-P — July 2005
5-32 Ultra1500 Application Examples
Figure 5.13
Velocity Regulator Step Response with Varying Integrator Time
Integrator Mode 
The Integrator Mode parameter controls how the integral term is applied to 
the velocity regulator. It can be set to Always On, High Current Disable, 
Velocity Command Disable, or Position Error Disable. This parameter 
introduces a nonlinear control to the integrator (preventing it from integrating 
in certain conditions) that may be useful in reducing or eliminating overshoot 
in the velocity response from integrator windup. Integrator windup occurs 
when the current regulator is saturated but the velocity error is not eliminated, 
and usually causes overshoot during command changes
Velocity 
Command
I = 0
I = 100
I = 10
I = 1
Integrator Time = 0
Integrator Time = 1
Time (msec)
020406080
0
50
100
150
200
450
400
350
300
250
Velocity
Integrator Time = 100