The gas supply pipe must be suciently sized to supply the BTU/h specied on the rang plate, based on
the
length of the piping run. The quick disconnect must not be installed in an upward direcon and a read
ily accessible
manual shut-o valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The
f
lared end of the hose must be connected to the ng on the end of the manifold tube or ex tube (if appli
cable)
as illustrated in the Natural Gas Hose Aachment diagram. Tighten using two wrenches. (Do not use thread
sealer/pipe dope.) Leak test all joints prior to using the gas grill.
WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak tested before
operang the grill.
Do not route hose underneath the drip pan.
Do not route hose between boom shelf space and back panel.
Do not route hose over top of rear panel.
Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope on
any hose connecon.
Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a re.
Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons found in
the manual.
The outdoor cooking gas appliance and its individual shuto valve must be disconnected from the gas supply
piping system during any pressure tesng of that system at test pressures in excess of 0.5 psi (3.5 kPa).
The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its individual
manual shuto valve during any pressure tesng of the gas supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa).
Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames are
in the area while you check for leaks. Sparks or open ames will result in a re or explosion, damage to
property, serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak Tesng
Dia
gram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one recommended
by the Customer Care department and have the grill inspected by a cered gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill inspected
by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.