Instruction manual
5
www.ultrachefgrills.com
: This natural gas grill is supplied with a 10 (3m) supply hose (complete with a quick
disconnect) designed for natural gas and cered for outdoor use. The gas grill is designed to operate at an
inlet pressure of 7 inches water column. Piping and valves upstream of the quick disconnect are not supplied.
The installaon must comply with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the
Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. The quick disconnect
must not be installed in an upward direcon and a readily accessible manual shut-o valve must be installed
upstream of, and as close to, the quick disconnect as is feasible. The ared end of the hose must be connected
to the ng on the end of the ex tube as illustrated in the Natural Gas Hose Aachment diagram. Tighten
using two wrenches. (Do not use thread sealer/pipe dope.) These connecons must be made by a licensed gas
installer. Leak test all joints prior to using the gas grill.
: Connect the ared end of the hose to the ng on the end of the manifold tube.
Wrench ghten. (Do not use thread sealer/pipe dope.)
: Connect the 20 inch hose from the manifold, to the side burner as illustrated in the Natural
Gas Hose Aachment diagram. Connect the supply hose to the are connecon, which faces down from the
side burner. Tighten all connecons using two wrenches. (Do not use thread sealer/pipe dope.)
• The installaon must be performed by a licensed gas er, and all connecons must be leak tested before
operang the grill.
• Do not route hose underneath drip pan.
• Do not route hose between space in boom shelf and back panel.
• Do not route hose over top of rear panel.
• Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope on
any hose connecon.
• Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a re.
• Leak test all the connecons using a soap and water soluon, as per the leak tesng instrucons found in
this manual.
: This must be done before inial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak Tesng
Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one recommend-
ed by the Customer Care department and have the grill inspected by a cered gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill inspected
by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.