: This natural gas grill is supplied with a 10 (3m) supply hose (complete with a quick
disconnect) designed for natural gas and cered for outdoor use. The gas grill is designed to operate at an
inlet pressure of 7 inches water column. Piping and valves upstream of the quick disconnect are not supplied.
The installaon must comply with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the
Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. The quick disconnect
must not be installed in an upward direcon and a readily accessible manual shut-o valve must be installed
upstream of, and as close to, the quick disconnect as is feasible. The ared end of the hose must be connected
to the ng on the end of the ex tube as illustrated in the Natural Gas Hose Aachment diagram. Tighten
using two wrenches. (Do not use thread sealer/pipe dope.) These connecons must be made by a licensed gas
installer. Leak test all joints prior to using the gas grill.


: Connect the ared end of the hose to the ng on the end of the manifold tube.
Wrench ghten. (Do not use thread sealer/pipe dope.)
: Connect the 20 inch hose from the manifold, to the side burner as illustrated in the Natural
Gas Hose Aachment diagram. Connect the supply hose to the are connecon, which faces down from the
side burner. Tighten all connecons using two wrenches. (Do not use thread sealer/pipe dope.)

The installaon must be performed by a licensed gas er, and all connecons must be leak tested before
operang the grill.
Do not route hose underneath drip pan.
Do not route hose between space in boom shelf and back panel.
Do not route hose over top of rear panel.
Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope on
any hose connecon.
Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a re.
Leak test all the connecons using a soap and water soluon, as per the leak tesng instrucons found in
this manual.






: This must be done before inial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak Tesng
Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one recommend-
ed by the Customer Care department and have the grill inspected by a cered gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill inspected
by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.