Specifications
Quick Operation Guide of DS-7200-SH/SV Series DVR
6 Alarm In/Out Connector for alarm input/output.
7 AUDIO IN RCA connector for audio input.
8 AUDIO OUT RCA connector for audio output.
9 LAN Interface Connector for LAN (Local Area Network).
10 RS-485 Interface Connector for RS-485 devices. Connect the D+ and D- terminals to T+
and T- of PTZ receiver respectively.
11 12V 12VDC power supply.
12 POWER Switch for turning on/off the device.
13
GND Ground (needs to be connected when DVR starts up).
Peripheral Connections
Connecting to Alarm Input / Output Device
The alarm input is an open/closed relay. If the input is not an open/closed relay, follow the connection diagram
below:
To connect to an AC/DC load, use the following diagram:
For DC load, JP4 can be used within the limit of 12V/1A safely. If the interface is connected to an AC load, JP4
should be left open. Use an external relay for safety (as shown in the figure above).
There are 4 jumpers (JP4, JP5, JP6, and JP7) on the motherboard, each corresponding with one alarm output. By
default, jumpers are connected. To connect an AC load, jumpers should be removed.
Note:
An external relay is needed to prevent electric shock when connecting to an AC load.
Alarm Connection
To connect alarm devices to the DVR:
5