Specifications
Preservation for long time storage
The following precautions must be taken when storing
equipment outside for more than 6 months. The interval 6
months must be reduced to 3 months for places with
temperatures constantly below freezing or where high
atmospheric humidity constantly occurs.
Mechanical equipment
1. For the ultimate corrosion protection β fill the gear boxes
full, with type of lubricant prescribed in the lubrication
chart.
Alternatively add VCI additive (Volatile Corrosion Inhibitor)
to the oil in the gear box according to the manufacturerβs
recommendation. Dismantle the air filter/s and seal the pipe
fitting elbow after the VCI additive has been mixed.
3. Apply Tectyl 506 Multi Purpose Rust Preventive (part No.
5402101-540) to all springs, shafts, rollers and pinions of
metal.
4. Dismantle machinery and safety device and place them in a
temperature controlled store. The machinery and the safety
device must always be located in their normal operating
positions.
5. Examine the surface treatment and touch-up any damage.
Electrical equipment
1. Ensure that the VCI anti corrosion protection devices for
use in electrical cabinets and junction boxes are properly
replaced according to the recommendations in the
maintenance manual so that expected corrosion protection
is achieved (storage time included).
If electrical cabinet is to be dismantled β always store them
upright like they are installed on the hoist.
External electrical equipment such as limit switches must be
opened and sprayed inside with WD-40 silicone free contact
aerosol part No. 5402101-535.
2. Charge battery where applicable.
General
All equipment must be sheltered from the rain and not exposed
to the sun. Total covering by means of plastic sheeting or
tarpaulins must be avoided as this will result in moisture
accumulation due to condensation.