Specifications
ALIMAK 00000
Gate rollers and gate interlockings
Extensive wearing and damages on gate rollers or guide rails can
cause improper function of the interlocking’s safety circuits.
Avoid accidents by daily try to start the hoist with gate opened.
The hoist must not start.
If so – the cause of the failure must be determined and rectified.
Be sure to check only one switch at a time.
New gate rollers for replacement are now accomplished with
securing plates which visually indicate and mechanically prevent
more than maximum allowable play.
WARNING!
Unintended operation
Perform safety check daily.
Failure to follow this warning can cause death or
personal injury.
Interlock type solenoid lock
k 222
Pos. ”2”
(.39’’) 10 mm
20 mm
(.78’’)
Pos. ”1”
Pos. ”1”
Pos. ”2”
k 145
(.08 – .12’’)
2 – 3 mm
(.31’’) 8 mm
35 mm
(1.38’’)
Pos. ”1”
Check the adjustment of the N C el. switch:
Position ”1” = electric switch NOT activated.
Position ”2” = electric switch activated.
ATTENTION! Adjust the position of the NC
electric switch to be activated AFTER the hook
is operated.
Note that the NC switch MUST NOT be
activated when a closed and locked door
is pushed and pulled.
E 14
Vertical gate profile
Interlock type mechanical hook with compression
spring and monitoring electrical switch
ALIMAK 35340 - 1 /09