Specifications
Interval Part Instructions
53. Deformations/ Inspect the equipment visually in its entirety for deformation/mechanical
mechanical damage to mast tubes, diagonal members of the mast sections, mast ties,
damage gates, protective rails, floors, etc.
This inspection and any actions, which may be necessary after the inspection
must be performed by trained/authorized service personnel.
54. Corrosion, Inspect the equipment in its entirety for corrosion and wear on loadbearing
damage and force-absorbing components by the aid of an ultrasonic thickness mea-
and wear -suring instrument. This inspection and any actions which may need to be
taken after the inspection must be performed by trained/authorized service
personnel. A method for internal corrosion protection of the mast tubes is
available, please contact your ALIMAK representative.
55. Hoist mast Check that all screw joints of all racks and mast joints are properly tightened.
Also check the screw joints for attaching the mast in the base.
56. Lubricating See the instructions in the ”Lubrication diagram”.
57. Centrifugal Dismantle the brake motor from the centrifugal brake and inspect the brake
brake – where hub with linings. See the instructions in the under heading ”Optional
applicable centrifugal brake”.
58. El./hydraulic Check the hydraulic system’s chock load valve. The load ramp must be able
operated load to close with a 20 kg weight placed farthest out on ramp. But NOT be able to
ramp – where closed if the weight exceeds 25 kg or more. For further details, see end of
applicable this chapter.
59. Hydraulic oil Check the hydraulic oil level on the buffer’s dip stick and refill, if necessary.
buffers – where Make a test run with the hydraulic buffer’s limit switch in ’’Off ’’-position
applicable The hoist must NOT start. Put suitable object between the hydraulic buffer’s
push rod and the limit switch’s actuator during the test.
Annually 60. Complete hoist Have the complete hoist checked by a qualified technician.
61. Corrosion Replace the corrosion protection devices which are located inside the elec-
protection trical panels according to the following:
devices Main panel (M-panel) 2 pcs. P/N 3002 301-105
Car top control panel (VFC) 2 pcs. P/N 3002 301-105
Car top control panel (DOL) 1 pcs. P/N 3002 301-101
Base panel (B-panel) 1 pcs. P/N 3002 301-105
Landing control stations 1 pcs. P/N 3002 301-101
Every 4th year 62. Safety device Replace the complete safety device by returning the device to the
or latest according Alimak Factory. Only Alimak factory tested devices are to be used.
to sign on the The safety device is sealed and unsealing the device is prohibited.
safety device
E 5