5.2 Placing
Position the welding power source such that its cooling air inlets and outlets are not
obstructed.
5.3 Mains power supply
Check that the unit is connected to the correct mains power
supply voltage, and that it is protected by the correct fuse sizes.
A protective earth connection must be made, in accordance
with regulations.
Rating plate with supply connection data
Recommend ed fuse sizes and minimum cab le areas
AristoMig U400 400 V 3ยต 50 Hz
Mains voltage 400 V
Mains cable area, mm
2
4G4
Phase current, I RMS 22 A
Fuse
Anti--surge
Type C MCB
25 A
32 A
NB: The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
5.4 Terminating resistor
In order to avoid communication interference, the ends
of the CAN bus must be fitted with terminating
resistors.
One end of the CAN bus is at the control panel, which
has an integral terminating resistor. The other end at
the power source must be fitted with the terminating
resistor, as shown on the right.