Instruction manual

HDE-3000 - 90 -
• Enter Newswire/Real Time Caption/Text
Syntax: [SOM] 2 <output> <dataservice> <rows> [CR]
<caption/text line> [CR]
<caption/text line> [CR]
[EOM] [CR]
The caption/text lines input through the serial port are output to <output>. Output
delays may be included in the data portion as <^Bn> with n = 1-9 seconds.
If data service is T1 or T2, the display is in normal text (data is formatted for text and
sent to the T1 or T2 output queue). If data service is C1 or C2, the display is in roll-up
mode as specified by the <rows> parameter (data is formatted for roll-up caption and
sent to the C1 or C2 output queue).
The valid data range is: 0, 2, 10h - 0x7fh. Invalid data bytes are ignored. All
upstream caption/text data is lost while this command is active.
Errors: 1. Unrecognized command
2. Invalid command argument(s)
• Enter Pass Through Caption/Text
Syntax: [SOM] 3 <mode> <output> [CR]
<caption/text data> [EOM] [CR]
The caption/text data input through the serial port is output to <output> with varying
degrees of processing as determined by <mode>.
mode = 1 All data is allowed and passed.
mode = 2 Legal caption control codes are transmitted in the same field.
mode = 3 Same as mode = 2, except that control codes are automatically doubled.
mode = 4 Same as mode = 3, except that no non-caption codes are transmitted.
The valid data range is: 0, 10h - 0x7fh. Invalid data bytes are ignored. All upstream
caption/text data is lost while this command is active.
Errors: 1. Unrecognized command
2. Invalid command argument(s)