Instruction manual
HDE-3000 - 88 -
Appendix D. EDS400 Command Set
Features/Definitions
• Command syntax:
An RS-232 command can have one of two formats:
1. [SOM] [command number] <command parameters> [CR]
2. [SOM] [command number] <command parameters> [CR]
<caption/text data> [EOM] [CR]
Spaces (20 hex), tabs (09 hex), or commas (2C hex) can be used to separate
command parameters. The encoder will acknowledge a valid command with [CR][LF]. If
a command error occurs, it will respond with [CR][LF][error code]. If an invalid command
number is received, it will respond with [CR][LF]1. The encoder uses XOFF/XON flow
control to prevent buffer overflow.
Definitions:
SOM Start Of Message: ^A (01 hex)
EOM End Of Message: ^C (03 hex)
ACK Acknowledge: ^F (06 hex)
CR Carriage Return: ^M (0D hex)
LF Linefeed: ^J (0A hex)
XOFF Flow control stop character: ^S (13 hex)
XON Flow control start character: ^Q (11 hex)
[ ] indicates a mandatory parameter
<> indicates an optional parameter
Input input channel: O0, O2. (O1 and O3 not allowed); default: O0.
Output output channel: O0, O1, O2, O3; default: default: O0.
Dataservice caption/text data service: C1, C2, T1, T2; default: C1.
Rows height of caption roll-up window: 2, 3, 4; default: 3.
Mode data preprocessing mode: 1, 2, 3, 4; default: 4.
Count 0, 1; default: 1.
Text ASCII text.
Class XDS class id (2 digit ASCII hex #): 01, 03, 05, 07, 09, 0B, 0D.
Type XDS type id (2 digit ASCII hex #): 01-7F.
Repeat count "0001" - "FFFF" 0000 = repeat time, FFFF indefinitely.
Repeat time transmission repeat time, "HH:MM:SS" example "00:30:00").
Line VBI line: 10 – 24(SD) 9-20(HD).
Error code 0 - 9, A - Z.