User's Manual

1.Warm Tips
1)Confirm the voltage (12VDC) and differentiate positive anode and cathode of the
power supply.
2)About the wiring between the reader and the controller, the wire should be 22
AWG at least and the length should not exceed 100 meters.
3)When external power is used, suggest to use same power GND with controller
panel. It is recommended to use multi-strand twisted pair cable to connect card reader
to access controller.
4)There is no need to wire the LED and BEEP cables if you do not need the card
reader to prompt an authorized card through sound and light.
2.Introduction
The RFID card reader can't work-alone and it needs to work with Wiegand protocol
access controller, such as access control panel, fingerprint device or master controller.
It uses ST MCU to ensure stable performance, and low-power circuit makes the service
life longer.
3.Features
The maximum reading distance is 6cm.
Waterproof, conforms to IP66.
It is useful for safety door system, easy to connect and use.
Ultra-low power consumption, the standby current is less than 50mA.
Support wiegand 26bits or wiegand 34bits output format.
Fast response speed, the door opening time is less than 0.3s.
Widely used in factories, houses, residential quarters, offices, mechanical and electrical
control equipment and so on.
4. Specification
Working Voltage
12VDC
Static Current
≤50mA
Card Type
EM-ID
Frequency
125KHz
Working Temperature
-40℃~60
Working Humidity
10%-90%RH
Panel Material
PC
Waterproof Rating
IP66
Shell Material
PC + ABS
Shell Size
90x45x19mm
Output Format (Selectable)
Wiegand 26bits
Wiegand 34bits
Communication
Distance
<100M
Status Indication
Bi-color LED + Buzzer
Lead Cable Length
25cm
LED Status Indication
Red means standby, Green means activated/triggered