User Manual

备注
1. 材质:157g双铜纸
3. 印刷颜色:四色一专
3. 展开尺寸:160x960mm
4. 成品尺寸:160x120mm
5. 尺寸公差:±1 mm
6. 印刷偏位:<=0.5 mm
7. 套印偏位:<=0.35 mm
8. 成型工艺: 风琴折
9.
10.印刷油墨(成品)矿物油含量需满足MOSH(C16-C35)小于0.1%;MOAH(1-7芳香环)小于0.1%;MOAH(3-7芳香环)小于0.0001%。
0~6
6~30
30~120
120~300
300~450
450~600
DRAFT TOLERANCE
0.05
B
0.15
0.20
0.30
0.40
0.50
0.10
C
0.20
0.30
0.40
0.50
0.60
+
_
0.20
0.20
0.25
0.30
0.50
0.80
0.50
EPS EPE EPP BAG CTN LABEL
0.50
1.00
2.00
3.00
0.50
0.50
1.00
2.00
3.00
CRITICAL DIM. MARK *
0.50
0.50
1.00
2.00
3.00
3.00
5.00
10.00
15.00
20.00
1.00
1.00
2.00
3.00
0.05
A
0.10
0.15
0.20
0.25
0.30
SELECT
V
TOL.
Dim
变更日期版本 变更描述
设计者
2022.11.23A01 初始发行
张雪峰
2023.2.17A02 更改说明书文案内容以及转接线示意图
张雪峰
外表面视图
内表面视图
半穿刀
辅助线
V槽线
裁切线
压痕线
牙刀
画线
深圳市绿联科技有限公司
物料名称: GS1200 15053 美规 说明书
产品名称 料号 项目工程师 核准
GS1200 1200W
智能户外电源
王帅兵 曾李同
1:1
SCALE
SHEET
1/1
UNIT
mm
PANTONE 3415C
1024Wh | 1200W
PowerRoam Portable Power Station
Contents
User Manual | Model: GS1200
All data shown are based on UGREEN laborator y testing.
Actual results may vary according to specic circumstances.
1. Product Overview
4. Powering Your Devices
3. Recharging Your Power Station
6. Features & Operating Modes
5. App User Guide
10. Safety Instructions
2. Specifications
7. FAQs
8. Troubleshooting
9. What's In The Box
11. Warranty Information
01
02
02
05
07
07
09
10
11
12
13
01 0302 04 05
07
06
08 09 1110 12 13
Always-On Mode
Power Saving Mode
Remaining
Recharge Time
Overload
Warning
USB-C
Output
USB-A
Output
Car Charging
Output
AC
Output
Total Input
Power
Remaining
Battery Level
Total Output Power /
Error Code
Remaining
Discharge Time
Wi-Fi Connection Status
Bluetooth Connection Status
Ventilation Fan Status
High-/Low-Temperature
Warning
Press to turn on
Press and hold for 3
seconds to turn off
In the standby state,
press to turn on.
Press again to turn off.
In the standby state,
press to turn on.
Press again to turn off.
The default state is ON,
double-press “DC” button to turn off.
3S
×1
SOS
Low Light
High Light
Flash
SOS
Off
(or press and hold for 3 seconds)
Car Charging Cable
SpeakerProjector
×1
×1
×2
Product Overview Powering Your DevicesSpecifications
Recharging Your Power Station
Flashlight
Product Details
LCD Display
Flashlight
LCD Display
Car Charging Output Port
Ventilation Outlet
Flashlight Power Button
IoT Button/ IoT Indicator
USB-C Output Ports × 2
Main Power Button/Power Indicator
USB-A Output Ports × 2
DC Power Button/DC Output Indicator
DC5521 Output Ports × 2
AC Power Button/AC Output Indicator
AC Output Outlets × 6
Overcharge Protection Switch
AC Input Outlet (Utility Power)
DC Input Port (Solar/Car Charging)
Protective Earth Screw
Ventilation Outlet
· Before charging, please make sure the power station is properly grounded.
· Please use an original or safety-certified power cable that meets the charging specifications of this
power station.
· When charging, ensure that the power station is well-ventilated and free from combustibles.
General Info
Safety Precautions
To charge power station via vehicle cigarette lighter port:
1. Please start the vehicle before recharging the power station with car charging cable. This will prevent
vehicle failure to start due to insufficient battery.
2. Please ensure cigarette lighter port and the car charging cable are properly connected.
Tips:
While powered on, if the power station is not used within 1 minute, the display automatically turns off.
Press any button to turn display on.
Tips:
· To switch AC output frequency, press and hold the AC Power Button for 10 seconds while the AC output
is off.
· Please check the rated frequency of the device before use. Improper frequency settings will result in
damage to the power station and connected device(s).
In the standby state, you can switch between the 5 states.
Car Recharging
Power On/Power Off
AC Output
Car Charging Output / DC5521 Output
USB Output
Input
Output
Working Environment Temperature
Dimensions
Net Weight
Lithium Battery
Rated Energy
AC
Solar
DC/Car Charger
AC (×6)
USB-A (×2)
USB-C (×2)
Car Charger (×1)
DC5521 (×2)
Total Output Power
Single-Port: 5V 3A/9V 2A/12V 1.5A/5V 4.5A
22.5W Max (Dual-Port: 45W Max)
Single-Port: 5V 3A/9V 3A/12V 3A/15V 3A/20V 3A/20V 5A
100W Max (Dual-Port: 200W Max)
12V 10A 120W Max
Single-Port: 12V 5A 60W Max (Car Charger + DC5521 × 2 = 120W Max)
1565W Max
Charging Temperature 0℃~40℃ (32℉~104℉)
34 × 22 × 27 (cm) / 13.4 × 8.7 × 10.6 (inch)
11.5 kg / 25.4 lbs
1024Wh 40Ah 25.6V
100-130V~ 60Hz 15A Max
12-48V 15A 400W Max
12V / 24V 8A Max
Car Refrigerator
USB Fast Charging Cable
Laptop Mobile
Phone
Digital
Camera
Power Reduction
Mode
Safety Instructions
Features & Operating Modes
Factory Reset
Troubleshooting
What's In The Box
FAQs
Power Reduction Mode
0% Battery Emergency Mode
Operating Modes
Warnings
· This power station contains a lithium battery; please do not disassemble, violently impact, or squeeze
the power station.
· Do not throw the power station into fire, or use it in situations of high temperature and during short
circuit.
· Do not insert foreign objects or fingers into the power station or use sharp objects to puncture it, so as
to avoid damaging the power station or unintentionally causing an explosion due to abnormal use or
short circuit.
· If the power station accidentally falls into water, it should be immediately moved into a safe, open area
until it is completely dry. Do not use it again. Dispose of it properly according to the Disposal Guide
detailed in this manual.
· Due to the particularity of the power station (built-in battery, high-voltage, etc.), please keep the power
station out of reach of children and pets. Special groups are recommended to use it under the
protection and supervision of a designated guardian.
Transportation & Storage
· Do not store or transport this power station with metal objects (glasses, watches, metal necklaces,
hairpins, etc.).
· If you want to ship this power station via logistical means, please discharge the power station battery to
10%~30%.
· This power station cannot be carried on a plane. Please abide by the relevant regulations of civil
aviation transportation.
Maintenance
· For long-term storage, please put the power station in the storage bag. Please charge and discharge at
least once every 3 months (discharge to 30%, then charge it to 60%) to ensure battery health.
· For long-time storage, please check the power stations remaining battery level. If it shows a low battery,
please charge first, otherwise the battery may be damaged.
· Please store the power station at the appropriate storage environment temperature (20℃~25℃/68°F-77°F)
specified in this manual.
· If the port of the power station is dirty, please clean with a dry cloth. Do not clean with chemicals or spray
cleaners.
Disposal
· Please dispose of this power station in accordance with local laws and regulations regarding battery
recycling and disposal. Do not dispose of it in ordinary trash.
· Be sure to fully discharge the battery of this power station before disposing of it in the designated battery
recycling bin.
· If the battery cannot be completely discharged due to product failure, please contact a professional
battery recycling company for further processing.
Warranty Information
A limited 5-year warranty applies to all UGREEN portable power stations purchased from UGREEN and
authorized sellers. Please feel free to contact us if you run into any problems.For more details on the
warranty, please visit: www.ugreen.com
Disclaimer
Before use, please read this manual carefully, and use the power station correctly in accordance with all
safety instructions in this manual. Relevant safety precautions especially must be followed. After reading,
please keep the manual for future reference.
To the extent permitted by law, improper use of this power station may directly or indirectly result in
damages to the power station and/or personal property and cause personal injury. UGREEN will not
assume any legal responsibility. Under the condition of compliance with laws and regulations, UGREEN
has the final right to interpret this manual and other related documents of this power station. The User
Manual is subject to update, revision, or termination without notice, but updates can be received via the
"UGREEN" App, or https://www.ugreen.com/.
Notes for Safe Use
· Do not place heavy objects on this power station.
· Please use the power station in a dry and well-ventilated environment. While in use, ensure the
ventilation outlets of the power station are not blocked.
· Do not place the power station near sources of heat or fire, such as microwave ovens, pressure cookers,
heating furnaces, etc. If the power station catches fire, please use fire extinguishing equipment as
quickly as possible.
· Do not expose the power station to any liquids and do not use it in rainy or humid environments.
· If the power station is subjected to strong impact or fall, do not continue normal use. Please dispose of
it properly according to the Disposal Guide in this manual.
· Do not use this power station in environments of strong electrostatic or electromagnetism.
· When not in use, please remove the power cord of the power station and all connected external
devices. When unplugging the power cable, please pull it out from the plug directly, rather than pulling
on the cord.
· Do not use non-UGREEN cords or parts. If repair or replacement parts and/or accessories are required,
please contact UGREEN customer service.
· Do not use a damaged power cable to charge the power station.
· Please use the power station at the specified working environment temperature.
While the U-Turbo Mode is active, the AC output ports of the power station can support devices with
power ratings of up to 2500W.
This mode allows for flashlight and USB ports usage when battery level is at 0%.
When powered on, press and hold the DC Power Button and Flashlight Power Button for 10 seconds at the
same time to enable this mode. After use, press and hold the Main Power Button for 3 seconds to disable.
Q1: What devices can be connected to the AC Output Port of the power station?
A1: The rated power of the AC output port of this power station is 1200W, which can power most
electronics, but it is recommended that you confirm the power of the device before use and ensure
that the sum of the power of all load devices is less than the rated power. When turning on the
U-Turbo function, AC output port of the power station can support heating devices with a rated power
of up to 2500W. But the function is not suitable for all devices. Inductive and high-power devices such
as air conditioners, coffee machines, and clothes dryers are not recommended.
Q2: Can I recharge the power station while charging connected devices?
A2: Yes. It is not recommended to power high-power devices when using this feature.
Q3: How do I know how long the power station can power devices?
A3: After a device is connected, the estimated remaining discharge time for the power station will be
shown on the display. This is calculated based on the actual power of the connected device and the
remaining battery level of the power station. If the actual power of the connected device is high and
the power station's remaining power is low, the remaining discharge time is short.t.
Q4: Why does the fan turn on during use?
A4: The fan automatically turns on to cool the power station, which is normal and provides a safer charge.
You can reduce the sound caused by the fans by turning on [Quiet Mode] in the "UGREEN" App [Settings].
Q5: Why does the power station run out of battery even when no device is connected?
A5: When the AC Output Outlets are on, even if no device is connected, there will be a certain amount of
no-load power consumption. To avoid this, please ensure the AC Output Outlets are turned off when
not in use to conserve battery.
To perform a factory reset, ensure the power station is not connected to any other device/appliances/etc.
Press and hold the AC Power Button and the DC Power Button simultaneously for 10 seconds to restore
the power station to factory settings.
Do not use UPS features in situations or with devices that require extreme reliability and/or security.
Examples include but are not limited to:
· Use with life-saving medical equipment like medical ventilators;
· Use in situations or environments that may cause severe bodily harm/injury (such as on airplanes,
ships, railways, elevators, etc.).
For safe use, Power Reduction Mode will automatically turn on in the following 4 states:
1. Low temperature
2. High temperature
3. Low battery charging
4. Trickle charging
(The Power Reduction Mode icon on the LCD display illuminates to indicate that the mode is on.)
This power station is not intended for use in any high-risk activities, such as activities where equipment
failure can directly result in death, personal injury, substantial property damage, or activities that affect
the operation of medical or similar equipment. UGREEN expressly disclaims any express or implied
warranties of suitability for high-risk activities. Any such use is a misuse of the power station.
Tips:
· For a safer charge, the U-Turbo mode is temporarily disabled while the power station is simultaneously
charging and charging other devices.
· U-Turbo is enabled by default. You can disable it using the "UGREEN" App.
· If the U-Turbo Mode is on, it is recommended to connect only one device to the AC output port to avoid
abnormal use of the power station.
· The AC output port can support devices up to 2500W like: hair dryers, electric kettles, etc., but U-Turbo
Mode is not applicable for all electrical appliances. Inductive and high-power devices such as air
conditioners, coffee machines, and clothes dryers are not recommended.
Tips:
· This mode is only available when the battery level is 0%.
· Please avoid using this mode frequently, as power station battery life could be negatively affected.
· After using this mode, promptly charge the power station, otherwise it may become unusable.
Note:
This operation will clear all network configuration data, function settings, etc. saved by the power station.
Perform reset with caution.
Note: In the case of an unsettled issue, please contact UGREEN Customer Service.
U-Turbo
Uninterruptible Power Supply (UPS)
Mode Description Setting
Standard
Mode
Power Saving
Mode
Always-On
Mode
In Standard Mode, the power station automatically shuts
down if there is no device connected and no operation is
performed within 5 hours after powering on
In Power Saving Mode, the power station
automatically shuts down if there is no device
connected and no operation is performed within 2
hours after powering on
In Always-On Mode, the power station remains on
until the battery is depleted or the power station is
manually turned off
Default mode
While power station is on,
double-press Main
Power Button to
enable/disable this mode
OVERLOAD
F05
F22
F33
F36
F37
F38
F39
+F03
+F10/F12/
F49
+F17/F50
Indicator Problem Solution
Remove all connected external devices from the
power station then restart the power station.
Please cease use immediately and contact
UGREEN Customer Service.
Battery is low, please charge promptly
Please cease use immediately and contact
UGREEN Customer Service.
Please check whether input voltage is within the
appropriate voltage range required by this manual.
If the input voltage is normal, please contact
UGREEN Customer Service.
Move the power station to a working
environment temperature as previously specified
by this manual before continued use.
Method 1: Open the App to enable Quiet mode.
Method 2: Stop charging the power station, turn it
off and wait 10 minutes before resuming charge.
Remove all connected external devices from the
power station, place the power station in a cool
and well-ventilated environment, then wait 10
minutes. After 10 minutes, turn it on again.
Discharging High
Temperature Protection
Discharge Undervoltage
Protection
Output Overload
1 × 1200W PowerRoam Power Station
1 × AC Power Cable 1 × Car Charging Cable
1 × Solar Parallel Adapter 1 × Accessory Storage Bag
1 × User Manual 1 × Warranty Card
1× DC5521 to DC5525 Cable
Low Temperature
Protection
Charging High
Temperature Protection
Temperature
Detection Failure
DC Output Failure
USB-A1 Output Failure
USB-A2 Output Failure
AC Charging Input Overvoltage
AC Charging Input Undervoltage
DC Charging Input Overvoltage
While power station is on,
press and hold AC power
button for 3 seconds to
enable/disable this mode
USER MANUAL
· Please store this power station in a dry place, at room temperature.
QSPEVDU!XBSSBOUZ!DBSE
App User Guide
To control the power station via mobile device, scan the QR code to download the “UGREEN” App:
Tip:
You can also search for "UGREEN" App via Apple Store or the Google Play Store.
120V~ 60Hz 10A 1200VA/1200W Max
Discharging Temperature -10℃~40℃ (14℉~104℉)
A B
· Please fully charge this power station before using it for the first time.
· In order to ensure safety while charging, overcurrent protection will automatically trigger when the
input current exceeds the overcurrent protection value. When this happens, the Overcharge Protection
Switch will protrude. Once the overcurrent is abolished, press the switch to resume charging.
· If the power station shows a low battery, please recharge promptly. Refraining from prompt recharge
may result in the battery becoming inoperable.
Recharge with PowerZip Fast Charging 1200W Max Input Power
To charge power station via solar panels, use the following configuration:
Important Note
AC Recharging
Solar Recharging
AC Power Cable
2 X 100W/200W Solar Panels
(not included)
solar parallel adapter and
solar charging cable
Note: Up to 4 pieces of 100W solar panels can be connected (Some cables are not included).
1 X 100W/200W Solar Panel
(not included)
or

Summary of content (2 pages)