User guide

Compact DMX+ Illuminator Range
15
MAINTENANCE
1) Unplug unit from electrical supply and allow to
cool.
2) On the rear of the unit, unscrew the two
knurled securing nuts (A) which hold the lamp
holder in position.
3) Use the handle (B) to withdraw the lampholder
from the light source.
4) Unplug the old lamp from its ceramic holder.
5) Plug the new lamp into the holder, making sure
that you use a lamp of the same
specification as to that which was removed.
Also make sure not to touch the glass part of
the lamp.
6) Slide the lamp holder plate back into position
carefully – making sure the lamp drawer
runners line up internally on the lampholder
slides. Push the drawer home firmly and
tighten the two retaining nuts.
NOTE: If the lamp does not strike aer
replacement check to see if the fans are
running. If the lamp is not striking and the fans
are not running, the lampholder drawer is not
properly inserted
.