Instruction Manual
Audible Continuity
Open circuit voltage: less than 700mV
Overload protection: 250V DC or 250V AC rms
Measurement Specifications
*Alignment marks
Position the conductor within the jaws at the intersection of the
indicated marks as much as possible in order to meet this meter’s
accuracy specifications.
If the conductor is positioned elsewhere within the jaws, the max.
additional error resulted is 1.5%.
*Accuracy: ±(% of reading + number of digits) at 64˚ to 82˚F (18˚ to
28˚C) with relative humidity to 80%.
AC Current
Frequency response: 50/60Hz
DC Voltage
Input impedance: 10MΩ
Maximum input voltage: 600V DC or 600V AC rms
AC Voltage
Input impedance: 10MΩ
Frequency response: 40~400Hz
Maximum input voltage: 600V DC or 600V AC rms
Resistance
Open circuit voltage: less than 700mV
Overload protection: 250V DC or 250V AC rms
UTL260-MAN P. 5
Range Resolution Accuracy
2A 0.001A
20A 0.01A ±(2%+5)
200A 0.1A
Range Resolution Accuracy
600V 1V ±(1%+5)
Range Resolution Accuracy
600V 1V ±(1.5%+5)
Range Continuity beeper
< approximately 50Ω
Range Resolution Accuracy
2kΩ 1Ω ±(1%+5)
MARK
CONDUCTOR
MARK
MARK