INSTRUCTION MANUAL UTL260 1-800-547-5740 • Fax: (503) 643-6322 www.ueitest.com • email: info@ueitest.
Introduction The UTL260 has all the features and measurement functions that appliance technicians need. It’s ruggedized and slim compact design makes for easy one handed use.
LCD Display Functional Description 1. Low battery indication 2. Hold data indication 3. C o n t i n u i tyfunction indication 4. Ohm measurement indication 5. Voltage measurement indication 6. Current measurement indication 7. DC input indication 8. AC input indication 9. Po l a r i tyindication 1 2 3 (Fig 1) DC Voltage Measurement 7 4 8 5 9 6 WARNING! Maximum input voltage of DC V range is 600V DC.
AC Voltage Measurement WARNING! Maximum input voltage of AC V range is 600Vrms. Do not attempt to take any voltage measurement that exceeds 600Vrms to avoid electrical shock hazard and/or damage to the instrument. 1. Set the rotary switch to the 600V~range. 2. Connect the black and red test leads to the “COM” and “VΩ” terminals respectively. 3. Connect the test leads to the circuit being measured and read the displayed value (Fig 3).
Maintenance Periodic service WARNING! Repair and service of this instrument is to be performed by qualified personnel only. Improper repair or service could result in physical degradation of the meter. This could alter the protection from electrical shock and personal injury this meter provides to the operator. Perform only those maintenance tasks that you are qualified to do.
Measurement Specifications *Alignment marks Audible Continuity MARK Range CONDUCTOR MARK Continuity beeper < approximately 50Ω Open circuit voltage: less than 700mV Overload protection: 250V DC or 250V AC rms MARK Position the conductor within the jaws at the intersection of the indicated marks as much as possible in order to meet this meter’s accuracy specifications. If the conductor is positioned elsewhere within the jaws, the max. additional error resulted is 1.5%.
UTL260 Digital Clamp-On Meter Limited Warranty The UTL260 is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi’s option.