User Manual

METER PROBLEM SOLVING
If any problems are not solved with these solutions, contact us or an authorized repair
center.
verify ProPer oPeratioN of ComBuStioN equiPmeNt
• Toverifythatequipmentisoperatingasthemanufacturedesignedittowork.Thisincludesinstallation
testsforCO2,O2,ExcessAirandstacktemperatures
- A properly tuned combustion appliance will perform better, and reduce the likelihood of
call-backs for no-heat
• Toverifythatthemaintenanceworkperformedhascorrectedtheproblem
• Todetectanydefectsearly–possiblyatinstallation
-Higherefficiencyequipmentisrunningatpeakonlywhenproperlyadjusted.Asthecomplexity
of a system increases, so does the importance of proper adjustment of the combustion process.
• Improperlyadjustedequipmentnotonlyfailstomeetexpectedperformancebutcouldleadtofuturefailures
• Tocheckthattheequipmentissuppliedwithenoughcombustionair,make-upairandhasproper
venting to exhaust the combustion by-products
• Toestablishabase-lineofdesiredperformance
- By tracking the performance over time you are able to see changes before they lead to
equipmentfailure.
verify Safe oPeratioN of ComBuStioN equiPmeNt
• Equipmentthatisnotproperlyadjusted,orthathasinsufficientdrafttoventcombustiongasescould
producecarbonmonoxideindeadlyquantities.TheUEiCO91(SoldSeperately)testbothfluegasand
ambient
 • Whencustomerscomplainaboutfumesitisusuallyanindicationofimproperoperation.COisa
colorless, odorless gas so the fumes are not the CO, but an indication that a problem may exist.
imProve your ProduCtivity & Profit
• TheUEiSmartBell combustionmetergivesaquick,continuousreadoutofthecombustionprocess.
Readings change in real-time as adjustments are made to help zero in on the proper setting. Compare
this to spot tests or other methods, and you will see your productivity rise.
• Propertestingwithdocumentedresultswillhelpyouprovidetheproperserviceorequipmentreplacement
recommendations,andhavethedatatosupportthis.Saleswillincreasebecauseyouarenolonger
guessing, and the work provided is proper for the needs of the customer.
• Customersonaservicecontractwillbeprovidedexcellentservice,andyouwillquicklydiagnosefailures
andhelpkeeptheequipmentupfortheseason.
imProve CuStomer PerCePtioN of your ServiCeS
• Provideyourcustomersresultsoftheperformanceoftheirequipment
 • Reduceyourcustomersenergyexpensebyproperlyadjustingandmaintainingtheirequipment
• Increaseyourconfidenceintheworkperformedandremember
if you doNt teSt, you doNt kNow
Fault symptom Causes / Solutions
CO2 too low • Air leaking into probe, tubing, water trap
or connectors.
CO2 reading (- - - -) • Meter was stored in a cold environment and
is not at normal working temperature.
Batteries not holding charge Batteries exhausted.
Meter does not respond to flue gas • Particle filter blocked.
• Probe or tubing blocked.
• Pump not working or damaged with
contaminants.
Net temperature or Efficiency • Ambient temperature set wrong during
calculation incorrect. Automatic Calibration.
Flue temperature readings erratic • Temperature plug reversed in socket.
• Faulty connection or break in cable or plug.
T flue or T nett displays (- - - -) • Probe not connected or faulty
X-Air, EFF display • CO2 reading is too low.
(- - - -)
7