User Manual
parameter reSolutioN accuracy raNGe
Gas MeasureMent
Carbon Monoxide *1 1ppM ±5ppM <100ppM 0-1999ppM
±5% rdg >100ppM
Carbon dioxide *1 0.1% ±0.3% 0-30%
oxygen *2 0.1% ±0.3% reading 0-21%
CalCulations
effiCienCy *2 0.1% ±1.0% reading 0-99.9%
exCess air *3 0.1% ±0.2% 0-250%
teMp MeasureMent
flue TeMperaTure 1.0 ˚f ±(2% rdg + 3.6˚f) 32-1112 ˚f
±(2% rdg + 2˚C) (0-600˚C)
pre-proGrammed fuelS naTural gas, lighT oil, propane, Wood, heavy oil.
DiMensions (approxiMaTe)
WeighT 1 lb
handseT 7” x 2” x 31/4”
probe 4” x 1/4” sTainless sTeel shafT
noMinal 36” neoprene hose.
aMbient operatinG ranGe +32o˚f To 104˚f
10% To 90% rh non- Condensing
850 To 1100 MMhg aTMospheriC pressure
battery life 4 aa Cells
>8 hours using alkaline aa Cells
*1 using dry gases aT sTp
*2 CalCulaTed
*3 CalCulaTed assuMing fuel lean CoMbusTion.
meter SpecificatioNS
(NOTE MAY BE SUBJECT TO CHANGE)
13