INSTRUCTION MANUAL RLD10 1-800-547-5740 • Fax: (503) 643-6322 www.ueitest.com • email: info@ueitest.
Introduction Controls and Indicators The RL D 10 makes pinpointing leaks as easy as one, two! Detect leaking refrigerant using the high sensitivity mode then switch to the low sensitivity mode to pinpoint its source. If background noise makes the audible tic hard to hear, you can count on the color scaled LED indicators.
*If the power-on indicator is a pinkish-red, the battery is becoming weak and should be replaced immediately. A low battery will adversely affect the instrument’s reliability. Each time the instrument is put into service, you can conduct a quick functional test. Simply allow the instrument to run through its self-calibration sequence in fresh air, then expose the sensor to an uncapped permanent marker (highlighters will not work).
Disassembly of Sensor 1. Turn the instrument’s power off. Mild electrical shock may result if you make contact with the sensor while power is on. 2. Remove the tip guard from the metal tip housing by twisting it clockwise while away from the Gooseneck. 3. Remove the metal tip housing from the Gooseneck by holding the Gooseneck steady while turning the tip housing counterclockwise. • The base contact assembly may adhere to the tip housing as it comes out.
Physical Characteristics Size: Height by Width by Depth (with probe wrapped around boot) Probe length: fully extended Weight (battery installed) 8” x 4” x 1 1/2” 18 1/2” (47cm) 14.1 Oz (400g) Functional Characteristics Power requirements Average battery life (Continuos use) Leak detection sensitivity Sensor Duty cycle Typical response time Warm up period Sensor output (voltage/current) Visual level indicators RLD10-MAN One 9 volt alkaline battery Approximately 8 hours .
RLD10 Refrigerant Leak Detector Limited Warranty The RLD10 is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi’s option.