User Guide

DL479
NCV
°C°F
CAT IV 600V
CAT III 1000V
MAX
µA
A
CAT Ill
1000V 600A
True RMS
Hz / Duty
MAX/MIN
AC/DC Voltage: <750V AC/600V DC
Default =
Press x1 =
WARNING
Use CAT III rated Test leads or higher.
Do not attempt to measure more than 750V AC/600V DC.
Keep hands below line when measuring high current levels.
Do not exceed 600 volts AC or DC – RMS at either the common or
multifunction input ports as measured from earth ground.
Select AC or DC Voltage.
WARNING
High Voltage indicator will display and audible alert will sound over 600V
AC/DC and High Voltage indicator will display (without audible alert) over
30V AC/DC.
Features:
DC Volts
Range Resolution Accuracy Overload Protection
600mV 0.1mV
±(0.5% +4 dgts) 1000V RMS
6V 1mV
60V 10mV
600V 100mV
AC Volts (45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
600mV 0.1mV
±(1.0% + 3 dgts) 1000V RMS
6V 1mV
60V 10mV
600V 100mV
750V 1.0V
True RMS Frequency Range: Square 50Hz to 100Hz
Sine 50Hz to 400Hz
Bandwidth: Sine = 0.5% error at 1.5kHz (max)
Square = 0.5% error at 0.1kHz (max)
Triangle = 0.5% error at 1.2kHz (max)
DL479
NCV
°C°F
CAT IV 600V
CAT III 1000V
MAX
µA
A
CAT Ill
1000V 600A
True RMS
Hz / Duty
MAX/MIN
Range Resolution Accuracy Overload Protection
600Ω 0.1Ω
±(0.8% +3 dgts)
600V RMS
6kΩ
60kΩ 10Ω
600kΩ 100Ω
6MΩ 0.001MΩ
60MΩ 0.01MΩ ±(1.2% +3 dgts)
Resistance: <60MΩ
Features:
WARNING
Do not measure resistance on a live circuit.
Default =
Press x1 =
Press x2 =
Press x3 =
Buzzer sounds at less than 40Ω.
WARNING
Do not measure resistance on a live circuit.
Features:
Open Circuit V Response Time Overload Protection
<1.0V <50ms 600V RMS
Default =
Press x1 =
Press x2 =
Press x3 =
Continuity
DL479
NCV
°C°F
CAT IV 600V
CAT III 1000V
MAX
µA
A
CAT Ill
1000V 600A
True RMS
Hz / Duty
MAX/MIN
M