Product Overview
WWW.UEITEST.COM USA 1.800.547.5740
CANADA 1.877.475.0648
Digital Pocket Psychrometer
DTH35
Specifications
Copyright © 2019 Kane USA Inc. All Rights Reserved.
Support Files
• Main photo: https://www.ueitest.com/ecommerce/site/content/PDFs/DTH35/DTH35_PP_A_VP.png
• Application photos: https://www.ueitest.com/ecommerce/site/images/thumbnails/
DTH35/652bdfdbef6e0c8742af21207114d9b6/600x600.0/DTH35-1.png?132507252862948277
• https://www.ueitest.com/ecommerce/site/images/thumbnails/DTH35/652bdfdbef6e0c8742af21207114d9b6/600x600.0/DTH35-3.
png?132507252876386178
• Includes photo: https://www.ueitest.com/ecommerce/site/images/thumbnails/
DTH35/652bdfdbef6e0c8742af21207114d9b6/600x600.0/DTH35-3.png?132507252876386178
• Data sheet: https://www.ueitest.com/ecommerce/site/content/PDFs/DTH35/DTH35_WDS.pdf
• Manual: https://www.ueitest.com/ecommerce/site/content/PDFs/DTH35/DTH35%20Manual.pdf
Tair RH WBT DP Enthalpy
Range
-4.0° ~ 122.0ºF
(-20.0° ~ 50.0ºC)
0.1% ~ 99.9%
5.0° ~ 121.8ºF
(-15.0° ~ 49.9ºC)
-4.0° ~ 121.8ºF
(-20.0° ~ 49.9ºC)
-1.0 ~ 125BTU/LB
(-2.2 ~ 292KJ/KG)
Resolution
0.1ºF
(0.1ºC)
0.1%
0.1ºF
(0.1ºC)
0.1ºF
(0.1ºC)
0.1BTU/LB or KJ/
KG(measured value <100)
1 BTU/LB or KJ/KG(Other
range)
Accuracy
±1ºF (±0.6ºC)
(32 ~ 122ºF (0 ~ 50ºC))
±2ºF (±1.2ºC)
(Others)
±3.0%
(10 ~ 90% @ 77ºF (25ºC))
±5% (other)
±2ºF (±1.2ºC)
(RH: 20 ~ 90%)
±3.8ºF (±2.1ºC)
(RH: 10 ~ 20%)
±1.8ºF (±1.0ºC)
40 ~ 90 %
±3.6ºF (±2.0ºC)
20 ~ 40 %
±7.2ºF (±4.0ºC)
10 ~ 20 %
Max/Min function YES
Backlight Press any key to activate the blue backlight for 10 seconds
Auto power off
20 minutes
(“ON/OFF”+ “HOLD” > 2 seconds to power meter on and disable “Auto power off” function)
Low battery Low Voltage indicator
RH Calibration 2 points calibration (32.8% & 75.3%)
Battery life
(2pcs CR2032)
>110 Hours without backlight