Brochure

Dimension 7.20” (H) x 3.70” (W) x 1.70” (D)
Weight Approx. 16.2 oz
Battery 2 x LR03 (AAA) type 1.5V
Certification CE
Safety IEC 1010-1 (2001), UL 3111-1 (6, 1994),
EN 61010-1 (2001), CSA C22.2
No. 1010.1 (1992)
CAT I Over Voltage (Installation) CATEGORY I,
Pollution Degree 2 per IEC 1010-1
Compliance IEC 60529: IP67 (Ingress Protection rating)
Water Immersion (3’ up to 30 min)
No ingress of dust (20mBar up to 8 hrs.)
Accuracy is specified for ambient temperatures between 64˚F (18˚C)
and 82˚F (28˚C) for a period of 1 year. The above specifications do not
include thermocouple error.
Calibration
The Apollo Digital Thermometer’s annual calibration, starting one year
after purchase, is recommended to ensure that the
thermometer performs to its accuracy specifications.
To calibrate the thermometer, contact your nearest UEi distributor or
UEi Service Center at 1-800-547-5740.
Copyright © 2008 UEi. APOLLO Digital Thermometers™ is a trademark of UEi. All Rights Reserved. Specifications are subject to change without notice. L310 PARA110.30k 0508
DISTRIBUTED BY:
US
A
1-800-547-5740 • Fax: (503) 643-6322
www
.ueitest.com • Email: info@ueitest.com
CANADA 1-877-475-0648 • Vancouver Fax: (604) 278-8299
T
oronto Fax: (905) 238-5117
EUROPE +44 1707 375550 • Fax: +44 1707 393277
P
LEAS
E
RECYCLE
APOLLO SPECIFICATIONS
Measurement Range J-Type: -346˚ to +2192˚F (-210˚ to +1200˚C)
K-Type: -328˚ to +2498˚F (-200˚ to +1370˚C)
T
-Type: -418˚ to +752˚F (-250˚ to +400˚C)
E-Type: -238˚ to +1832˚F (-150˚ to +1000˚C)
D
isplay Resolution 0.1˚F/˚C < 1000˚
1.0˚F/˚C ≥ 1000˚
A
ccuracy J, K, T, and E-Type; ±[0.1% +1.0˚F (0.5˚C)]
[Below -148˚F (-100˚C): add 0.2% of reading
for J, K, and E-Type; and 0.1% of reading for T-Type]
Temperature 0.01% of reading 0.1˚F per ˚F(+0.05˚C per ˚C)
Coefficient for <+64˚F (+18˚C) or +82˚F (+28˚C)
[Below -148˚F (-100˚C): add 0.05% of reading
for J, K, and E-type; and 0.1% of reading for T-type]
Real Time About 1 second per day
Clock Tolerance
Maximum Differential 1V (maximum voltage difference between
Common Mode any pair of inputs)
Voltage
Temperature Scale ITS-90 (International Temperature Scale of 1990)
Applicable Standards N.I.S.T. Monograph 175 revised to ITS-90