DM515 True RMS 1000V Digital Multimeter w/Temperature INSTRUCTION MANUAL ENGLISH DM515 Apo V RANGE MIN/MAX HOLD FAST SEL °F°C µA A mA Temp 600V CAT III 1000V CAT II True RMS A mAµA 10A MAX FUSED 400mA MAX FUSED 1-800-547-5740 www.ueitest.com • email: info@ueitest.
TABLE OF CONTENTS FUNCTIONS .................................................................................................................................................. 3 FEATURES ..................................................................................................................................................... 3 GENERAL SPECIFICATIONS ..................................................................................................................... 3 CATEGORY DEFINITIONS...........
FUNCTIONS • • • • • 1000V AC/DC 10A AC/DC Resistance 40MΩ Diode test Audible continuity • • • • • • • True RMS Auto/Manual ranging Auto power off Min/Max Hold 1 ms Fast response Min/Max Low battery indicator • • • • Capacitance 9999µF Temperature -328˚ to 2462˚F (-200˚ to 1350˚C) Microamps Milliamps FEATURES • • • • • • Rubber boot Test lead holders Kick stand High resolution backlit display Fused test lead inputs Auto selection GENERAL SPECIFICATIONS • Operating Temperature: 32˚ to 122˚F (0˚ to 50˚
IMPORTANT SAFETY WARNINGS WARNING Read entire Safety Notes section regarding potential hazard and proper instructions before using this meter. In this manual the word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to indicate conditions or actions that may damage this instrument. WARNING To ensure safe operation and service of the tester, follow these instructions.
OVERVIEW J DM515 A Apo V K B C D E RANGE MIN/MAX HOLD FAST G H SEL L °F°C F M µA A mA N O Temp True RMS A mAµA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V I A. Apo: Auto power off after 30 minutes of use. Press and hold the HOLD button while turning the meter on to disable Apo. B. Digital Backlit Display C. Range Button • Press to change from auto ranging to manual ranging. • Press repeatedly to select proper range.
SYMBOLS nF Negative AC/DC Voltage or Current Auto-ranging Overload: Range Exceeded Auto power off Active Low Battery Hold/Capture Value Minimum measured value displayed Maximum measured value displayed Voltage A Amps Microamps mA Milliamps Diode Nano Farads Ohms/Resistance Continuity Degrees Fahrenheit Degrees Celsius Fuse Warning or Caution Ground High Voltage Indication µF Microfarad Auto Auto Selection Dangerous Levels AC/DC Voltage: <1000V AC/DC DM515 Apo V AT RANGE MIN/
Resistance: <40MΩ DM515 Apo V AT RANGE MIN/MAX HOLD FAST SEL °F°C °F°C Features: µA µA AA mA mA RANGE MIN/MAX HOLD Temp WARNING • Do not measure resistance on a live circuit. True RMS A mAµA MAX CAT III 600V 400mA MAX FUSED 10A MAX FUSED CAT II 1000V Ranges Accuracy Resolution Overload Protection 600Ω to 6MΩ 40MΩ ±(0.8% +5 dgts) ±(1.5% +5 dgts) 0.1Ω to 0.001MΩ 0.
Diode GOOD DIODE BAD DIODE Open Diode Displays "OL" Both directions DM515 Forward Bias Displays approx. voltage drop Apo V V RANGE MIN/MAX V or HOLD Apo V FAST SEL °F°C °F°C '0' Both directions (shorted) µA µA AA mA mA Reverse Bias Displays "OL" Apo • Forward voltage drop if forward biased. • “OL” if reverse biased. Temp True RMS A mAµA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V Features: MIN/MAX Open Circuit Voltage Overload Protection Approx.: <3.
AC/DC Microamps: 6000μA AC/DC Milliamps: 400mA DM505 DM515 DM505 DM515 Apo Apo V µ A AT RANGE MIN/MAX m AT HOLD RANGE MIN/MAX FAST HOLD FAST SEL SEL °F°C µA °F°C µA µA mA µA mA AA mA mAµA A V A 10A MAX FUSED 400mA MAX FUSED AA mA mAµA A MAX CAT III 600V µA CAT II 1000V 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V mA Keep hands behind test lead guards when measuring current levels.
AC/DC Amps: <10A DM515 DM505 Apo A V AT RANGE MIN/MAX HOLD FAST SEL µA WARNING Keep hands behind test lead guards when measuring current levels. • Do not attempt to measure more than 10A AC. mA A mAµA A 10A MAX FUSED AC AMPS Ranges 6A to 10A 400mA MAX FUSED MAX CAT III 600V CAT II 1000V A Features: Accuracy ±(1.5% +5 dgts) RANGE MIN/MAX HOLD SEL Resolution 0.001A to 0.01A Overload Protection 11A/1000V Fast fuse Resolution 0.001A to 0.
4mm Test Lead Notes CATIII 1000V Measurement Locations 4mm • Ensure the test lead shield is pressed firmly in place. Failure to use the CATIV shield increases arc-flash risk. CATII 1000V Measurement Locations 18mm 18mm • CAT IV shields may be removed for CAT II locations. This will allow testing on recessed conductors such as standard wall outlets. Take care not to lose the shields.
FCC/IC INFORMATION NOTE: This device complies with Part 15 of the FCC Rules and CAN ICES-3(A). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. INFORMATION TO THE USER This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.