User Guide
3
FUNCTIONS
FEATURES
•  1000V AC/DC
•  10A AC/DC
•  Resistance 40MΩ
•  Diode test
•  Audible continuity
•  Capacitance 9999µF
• Milliamps/Microamps
•  Auto/Manual ranging
•  Auto power off
• Min/Max
• Hold
•  1 ms Fast response Min/Max
•  Low battery indicator
•  Test lead holders
•  Kick stand
•  High resolution backlit display
•  Auto selection
•  Fused test lead inputs
•  Rubber boot
GENERAL SPECIFICATIONS
•  Operating Temperature: 32˚ to 122˚F (0˚ to 50˚C)
•  Storage Temperature: -44˚ to 122˚F (-20˚ to 50˚C)
•  Operating Humidity: <75% max.
•  Operating Altitude: 6561 ft (2000m)
•  Display: 6,000 count
•  Backlight: Yes
•  Over-range: “OL” is displayed
•  Dimensions: 6.49” x 3.3” x 2.17” 
•  Item Weight: 15.0 oz
•  Calibration: Recommended annually
•  CAT Rating: CAT III 600V/CAT II 1000V
•  Certifications: cELTus UL 61010-1:2012 3rd 
      CE EN 61010-1:2010 3rd, IEC61010-2-033:2012, Ed.1, EN 61326-1:2013       
      FCC, RoHS Compliant, TOV protection, IP 42, 6’ Drop protection 
•  Battery Type: (AA) 2
•  Test Leads: CAT III test leads
•  Accuracy: ± (% of reading + # of least significant digits)
Measurement Category Short-Circuit (typical) kA
a
Location in the building installation
II < 10
Circuits connected to mains socket outlets and similar 
points in the MAINS installation
III < 50 Mains distributions parts of the building
IV > 50 Source of the mains installation in the building
CATEGORY DEFINITIONS