INSTRUCTION MANUAL DM200 1-800-547-5740 • Fax: (503) 643-6322 www.ueitest.com • email: info@ueitest.
Introduction The DM200 ElectroMate™ will perform everyday basic electrical tests easily and economically. Connect the test leads, turn the DM200 on, set the function switch to the proper setting and you are ready to take AC/DC volt, c o n t i n u i tyor resistant measurements.
Continuity Testing 1. Connect the black test lead to the terminal marked “COM” and the red test lead to the terminal marked “V Ω“. 2. Set the rotary switch to the continuity/resistance function, and note the overload symbol on the display. 3. For continuity testing, touch the red lead to one side of the circuit (i.e. wire) and the black lead to the other side. Ensure your circuit is isolated from other circuit paths to prevent testing the wrong path.
DM200 Digital Multimeter Limited Warranty The DM200 is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi’s option.