User Guide

14
Use CAT III rated leads or higher.
Press the AC/DC volts button to select AC voltage, press and hold the button
for Frequency and Duty Cycle modes.
WARNING
Do not attempt to measure more than 750V AC/1000V DC.
Features:
RANGE
HOLD
MAX/
MIN
PEAK
Frequency
Range Resolution Accuracy Overload Protection
99.99Hz 0.01Hz
± (0.1% +3 dgts) 600V RMS
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
Duty Cycle
Range Resolution Accuracy Overload Protection
1.0 to 99.0% 0.1%
±(0.2% per kHz +
0.1% + 5dgts)
600V RMS
Frequency Sensitivity: 1.8Vrms
Frequency (Hz) / Duty Cycle
Default =
Press x1 =
Press and hold =
Press and hold x1 =
DL489 True RMS
600V 600A
CAT III
CATII 1000V
CATIII
600V
MAX
30V
T2
T1
TEMP
NCV
MAX/
MIN
PEAK
DC
Zero
INRUSH
T
e
m
p
/
°
F
°
C
μ
A
A
V
H
z
/
D
u
t
y
MFD
RANGE
S/N
Battery Replacement
When the batteries are too low for safe
operation, the Low Battery indicator will display
Remove the scews from the battery cover.
Remove battery cover.
Replace the old batteries with 6 new (AAA)
batteries.
Replace the battery cover.
Replace the screws.