Product Overview
WWW.UEITEST.COM USA 1.800.547.5740
CANADA 1.877.475.0648
True RMS Digital Clamp-On Meter
DL489
Specifications
Downloads
Copyright © 2017 Kane USA Inc. All Rights Reserved. L412
Manual
Data Sheet
Frequency
Range Resolution Accuracy Overload Protection
99.99Hz 0.01Hz
± (0.1% +3 dgts) 600V RMS
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
Duty Cycle
Range Resolution Accuracy Overload Protection
1.0 to 99%
±(0.2% per kHz +
0.1% + 5dgts)
600V RMS
Diode Test
Range Open Circuit V Test Current Overload Protection
3.0V <3.2V DC 0.25mA 600V RMS
Capacitance
Range Resolution Accuracy Overload Protection
10.00nF 0.01nF
± (3.0% +5 dgts) 600V RMS
100.0nF 0.1nF
1.000µF 0.001µF
10.00µF 0.01µF
100.0µF 0.1µF
2000µF 1µF
Continuity
Open Circuit V <1.00V Overload Protection
Threshold Appox. <40Ω 600V RMS
Temperature
Range Resolution Accuracy Overload Protection
-328˚F to 999˚F
(-200˚ to 999˚C)
0.1°F (0.1˚C)
±(1.0% +3.6˚F)
±(1.0% + 2.0˚C)
30V RMS
1000˚F to 2462˚F
(1000˚ to 1350˚C)
0.1°F (0.1˚C)
±(1.0% +3.0˚F)
±(1.0% + 2.0˚C)
AC Current
Range Resolution Accuracy Overload Protection
60A 0.01A
±(2.0% +8 dgts) 600V RMS
600A 0.1A
45Hz to 400Hz TRMS
Minimum current for Clamp measurement: 0.3A
DC Current
Range Resolution Accuracy Overload Protection
60A 0.01A
±(2.0% +8 dgts) 600V RMS
600A 0.1A
45Hz to 400Hz TRMS
Minimum current for Clamp measurement: 0.3A
AC Volts (45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
600mV 0.1mV
± (1.0% +3 dgts) 750V RMS
6V 1mV
60V 10mV
600V 100mV
750V 1.0V
45Hz to 400Hz True RMS
DC Volts
Range Resolution Accuracy Overload Protection
600mV 0.1mV
± (0.5% +4 dgts) 1000V RMS
6V 1mV
60V 10mV
600V 1000mV
1000V 1V ±(0.8% +5 dgts)
45Hz to 400Hz True RMS
DC Low Amps
Range Resolution Accuracy Overload Protection
600µA 0.1µA
± (1.2% +3 dgts) 2000µA/600V RMS
2000µA 1µA
45Hz to 400Hz True RMS
AC Low Amps
Range Resolution Accuracy Overload Protection
600µA 0.1µA
± (1.2% +3 dgts) 2000µA/600V RMS
2000µA 1µA
45Hz to 400Hz True RMS
Resistance
Range Resolution Accuracy Overload Protection
600Ω 0.1Ω
± (0.8% +3 dgts)
600V RMS
6kΩ 1Ω
60kΩ 10Ω
600kΩ 100Ω
6MΩ 1kΩ
60MΩ 0.01MΩ ± (1.2% +3 dgts)