Product Overview

DL49
400 Amps AC and DC
600 Volt AC and DC
Resistance to 40 Megohms
Continuity
Autoranging
AC Amps peak hold
Data hold
1 mV DC resolution allows use of
DMM adapters
1 1/4” Jaw capacity
CE and UL listed CAT III
Three year limited warranty
ATL55, AAC3, 9V Bat.,
Carrying Case
DL99B
True RMS
Work light and backlit display
1000 Amps AC and DC
1000 Volts AC and DC
Resistance to 40 kilohms
Continuity
Push-button ranging
Peak hold
Data hold
0.1 mV DC resolution allows use of
DMM adapters
1-3/8” jaw capacity
CE and UL listed CAT III
Three year limited warranty
ATL55, AAC3, 9V Bat.,
Holster
Range Resolution Accuracy Overload
AC Amps
400A 0.1A ±2.0% + 5 600V
1000A 1A
DC Amps
400A 0.1A ±2.0% + 5 600V
1000A 1A
AC Volts (50Hz ~ 400Hz)
400V 0.1V ±1.9% + 3 600V
1000V 1V
DC Volts
400mV 0.1mV ±1.0% + 2 600V
400V 0.1V
1000V 1V
Volts AC & DC auto ranges to 600V scale when >400V
Resistance
400Ω 0.1Ω ±1.0% + 2 600V
40kΩ 0.01kΩ
Continuity
400Ω 0.1Ω Tone Sounds @¯40Ω
DL99B
Range Resolution Accuracy Overload
AC Amps (50Hz ~ 400Hz)
40A 0.01A ±2.0% + 5 600V
400A 0.1A ±3.0% + 10
DC Amps
40A 0.01A ±2.5% + 10 600V
400A 0.1A ±1.5% + 5
AC Volts (50Hz ~ 400Hz)
4V 1mV ±1.5% + 3 600V
40V 10mV
400V 100mV
600V 1V
DC Volts
4V 1mV ±0.9% + 2 600V
40V 10mV
400V 100mV
600V 1V
Resistance
400Ω 0.1Ω ±0.9% + 2 600V
4kΩ
400kΩ 100Ω
4MΩ 1kΩ ±1.2% + 5
40MΩ 10kΩ
DL49