Product Overview
DL49
• 400 Amps AC and DC
• 600 Volt AC and DC
• Resistance to 40 Megohms
• Continuity
• Autoranging
• AC Amps peak hold
• Data hold
• 1 mV DC resolution allows use of
DMM adapters
• 1 1/4” Jaw capacity
• CE and UL listed CAT III
• Three year limited warranty
ATL55, AAC3, 9V Bat.,
Carrying Case
DL99B
• True RMS
• Work light and backlit display
• 1000 Amps AC and DC
• 1000 Volts AC and DC
• Resistance to 40 kilohms
• Continuity
• Push-button ranging
• Peak hold
• Data hold
• 0.1 mV DC resolution allows use of
DMM adapters
• 1-3/8” jaw capacity
• CE and UL listed CAT III
• Three year limited warranty
ATL55, AAC3, 9V Bat.,
Holster
Range Resolution Accuracy Overload
AC Amps
400A 0.1A ±2.0% + 5 600V
1000A 1A
DC Amps
400A 0.1A ±2.0% + 5 600V
1000A 1A
AC Volts (50Hz ~ 400Hz)
400V 0.1V ±1.9% + 3 600V
1000V 1V
DC Volts
400mV 0.1mV ±1.0% + 2 600V
400V 0.1V
1000V 1V
Volts AC & DC auto ranges to 600V scale when >400V
Resistance
400Ω 0.1Ω ±1.0% + 2 600V
40kΩ 0.01kΩ
Continuity
400Ω 0.1Ω Tone Sounds @¯40Ω
DL99B
Range Resolution Accuracy Overload
AC Amps (50Hz ~ 400Hz)
40A 0.01A ±2.0% + 5 600V
400A 0.1A ±3.0% + 10
DC Amps
40A 0.01A ±2.5% + 10 600V
400A 0.1A ±1.5% + 5
AC Volts (50Hz ~ 400Hz)
4V 1mV ±1.5% + 3 600V
40V 10mV
400V 100mV
600V 1V
DC Volts
4V 1mV ±0.9% + 2 600V
40V 10mV
400V 100mV
600V 1V
Resistance
400Ω 0.1Ω ±0.9% + 2 600V
4kΩ 1Ω
400kΩ 100Ω
4MΩ 1kΩ ±1.2% + 5
40MΩ 10kΩ