Product Overview

DIGITAL CLAMP METERS
DL369
DL235
4000µF Capacitance
2000µA AC/DC
Non-Contact Voltage 24~600V AC
750V AC/1000V DC
400A AC
MIN/MAX
40MΩ Resistance/Continuity
Frequency/Duty Cycle
Diode
Data Hold
True RMS
700 Amps AC and DC
750 Volts AC and DC
Resistance to 4 kilohms
Continuity
Frequency to 10 kilohertz
Dual Display
Low Battery Display Lock
Test Lead Storage
Test Lead Holder on Clamp Head
Auto Off
Three Year Limited Warranty
Auto or manual ranging
Soft mode smooths amp, frequency or
voltage readings
Crest mode displays 1/2 wave peak to
calculate crest factor
MIN/MAX record
2 1/6” jaw capacity
CE and CAT II
Five year limited warranty
ATL55, AAC3, 9V Bat,
Holster
ATL59, AAC3, ATT29, 2(AA) Bat.,
Zippered Carrying Case
Range Resolution Accuracy
*2
AC Amps (RMS Amperes)
*1
0.30 ~39.99 0.01A ±3% + 20 @ 45Hz ~ 65Hz
(40A scale) ±4% + 30 @ 30Hz ~ 45Hz
*3
±4% + 30 @ 65Hz ~ 1kHz
±8% + 30 @ 20Hz ~ 30Hz
*4
0.30 ~ 399.9A 0.1A ±3% + 2 @ 45Hz ~ 65Hz
(400A scale) ±4% + 3 @ 30Hz ~ 45Hz
*3
±4% + 3 @ 65Hz ~ 1kHz
±8% + 3 @ 20Hz ~ 30Hz
*4
400 ~ 700A 1A ±5% @ 45Hz ~ 65Hz
(400A scale) ±7% @ 30Hz ~ 45Hz
*3
±7% @ 20Hz ~ 30Hz
Not Specied @ 20Hz ~ 30Hz
*4
Range Resolution Accuracy
*2
Instantaneous Amperes (Crest Mode)
*1
0.4 ~ 39.99A 0.2A ±3% + 30 @ 45Hz ~ 65Hz
(40A scale) ±4% + 30 @ 30Hz ~ 45Hz
*2
±4% + 30 @ 65Hz ~ 1kHz
±8% + 40 @ 20Hz ~ 30Hz
*3
0.4 ~ 399.9A 2A ±3% + 3 @ 45Hz ~ 65Hz
(400A scale) ±4% + 3 @ 30Hz ~ 45Hz
*2
±4% + 3 @ 65Hz ~ 45kHz
±4% + 4 @ 20Hz ~ 30Hz
*3
400 ~ 699A 4A ±3% @ 45Hz ~ 65Hz
(400A scale) ±4% @ 30Hz ~ 45Hz
*2
±4% @ 65Hz ~ 1kHz
±4% @ 20Hz ~ 30Hz
*3
400 ~ 699A 4A ±7% @ 45Hz ~ 65Hz
(400A scale) ±7% @ 30Hz ~ 45Hz
*2
±7% @ 65Hz ~ 1kHz
±7% @ 20Hz ~ 30Hz
*3
Range Resolution Accuracy
Frequency
*1
0.5 ~ 999.9Hz 0.1Hz ±0.2% + 3
1,000 ~ 9,999Hz 1Hz ±0.2% + 3
DC Amps
0.30 ~ 39.99A (40A scale) 0.01A ±2% + 30
0.30 ~ 399.9A (400A scale) 0.1A ±2% + 10
400 ~ 700A (400A scale) 1A ±2% + 10
AC Volts
0 ~ 39.9V (40V scale) 0.01V ±1.0% + 3
0 ~ 399.9V (400V scale) 0.1V ±1.0% + 3 @ 45Hz ~ 65Hz
±2.5% + 5 @ 65Hz ~ 1kHz
0 ~ 750V (400V scale) 1V ±1.0% + 5 @ 45Hz ~ 65Hz
DC Volts
0 ~ 39.9V (40V scale) 0.01V ±1.0% + 3
0 ~ 399.9V (400V scale) 0.1V ±1.0% + 3
0 ~ 750V (400V scale) 1V ±1.5% + 5
DL235
*1. Sine wave, measured with conductor centered at alignment marks and battery life is greater than 40hrs on meter power up.
*2. RMS MIN/MAX: ADD 10 counts.
*3. 1A and above @ 30Hz ~ 45Hz
*4. Average only, 2.5A and above RMS MIN/MAX add 2% of reading