Product Overview
DIGITAL CLAMP METERS
DL369
DL235
• 4000µF Capacitance
• 2000µA AC/DC
• Non-Contact Voltage 24~600V AC
• 750V AC/1000V DC
• 400A AC
• MIN/MAX
• 40MΩ Resistance/Continuity
• Frequency/Duty Cycle
• Diode
• Data Hold
• True RMS
• 700 Amps AC and DC
• 750 Volts AC and DC
• Resistance to 4 kilohms
• Continuity
• Frequency to 10 kilohertz
• Dual Display
• Low Battery Display Lock
• Test Lead Storage
• Test Lead Holder on Clamp Head
• Auto Off
• Three Year Limited Warranty
• Auto or manual ranging
• Soft mode smooths amp, frequency or
voltage readings
• Crest mode displays 1/2 wave peak to
calculate crest factor
• MIN/MAX record
• 2 1/6” jaw capacity
• CE and CAT II
• Five year limited warranty
ATL55, AAC3, 9V Bat,
Holster
ATL59, AAC3, ATT29, 2(AA) Bat.,
Zippered Carrying Case
Range Resolution Accuracy
*2
AC Amps (RMS Amperes)
*1
0.30 ~39.99 0.01A ±3% + 20 @ 45Hz ~ 65Hz
(40A scale) ±4% + 30 @ 30Hz ~ 45Hz
*3
±4% + 30 @ 65Hz ~ 1kHz
±8% + 30 @ 20Hz ~ 30Hz
*4
0.30 ~ 399.9A 0.1A ±3% + 2 @ 45Hz ~ 65Hz
(400A scale) ±4% + 3 @ 30Hz ~ 45Hz
*3
±4% + 3 @ 65Hz ~ 1kHz
±8% + 3 @ 20Hz ~ 30Hz
*4
400 ~ 700A 1A ±5% @ 45Hz ~ 65Hz
(400A scale) ±7% @ 30Hz ~ 45Hz
*3
±7% @ 20Hz ~ 30Hz
Not Specied @ 20Hz ~ 30Hz
*4
Range Resolution Accuracy
*2
Instantaneous Amperes (Crest Mode)
*1
0.4 ~ 39.99A 0.2A ±3% + 30 @ 45Hz ~ 65Hz
(40A scale) ±4% + 30 @ 30Hz ~ 45Hz
*2
±4% + 30 @ 65Hz ~ 1kHz
±8% + 40 @ 20Hz ~ 30Hz
*3
0.4 ~ 399.9A 2A ±3% + 3 @ 45Hz ~ 65Hz
(400A scale) ±4% + 3 @ 30Hz ~ 45Hz
*2
±4% + 3 @ 65Hz ~ 45kHz
±4% + 4 @ 20Hz ~ 30Hz
*3
400 ~ 699A 4A ±3% @ 45Hz ~ 65Hz
(400A scale) ±4% @ 30Hz ~ 45Hz
*2
±4% @ 65Hz ~ 1kHz
±4% @ 20Hz ~ 30Hz
*3
400 ~ 699A 4A ±7% @ 45Hz ~ 65Hz
(400A scale) ±7% @ 30Hz ~ 45Hz
*2
±7% @ 65Hz ~ 1kHz
±7% @ 20Hz ~ 30Hz
*3
Range Resolution Accuracy
Frequency
*1
0.5 ~ 999.9Hz 0.1Hz ±0.2% + 3
1,000 ~ 9,999Hz 1Hz ±0.2% + 3
DC Amps
0.30 ~ 39.99A (40A scale) 0.01A ±2% + 30
0.30 ~ 399.9A (400A scale) 0.1A ±2% + 10
400 ~ 700A (400A scale) 1A ±2% + 10
AC Volts
0 ~ 39.9V (40V scale) 0.01V ±1.0% + 3
0 ~ 399.9V (400V scale) 0.1V ±1.0% + 3 @ 45Hz ~ 65Hz
±2.5% + 5 @ 65Hz ~ 1kHz
0 ~ 750V (400V scale) 1V ±1.0% + 5 @ 45Hz ~ 65Hz
DC Volts
0 ~ 39.9V (40V scale) 0.01V ±1.0% + 3
0 ~ 399.9V (400V scale) 0.1V ±1.0% + 3
0 ~ 750V (400V scale) 1V ±1.5% + 5
DL235
*1. Sine wave, measured with conductor centered at alignment marks and battery life is greater than 40hrs on meter power up.
*2. RMS MIN/MAX: ADD 10 counts.
*3. 1A and above @ 30Hz ~ 45Hz
*4. Average only, 2.5A and above RMS MIN/MAX add 2% of reading