User Guide

17257 • 0316
SYMBOLS
AC (Alternating current) DC (Direct current)
AC/DC
Polarity
Overload: Range Exceeded
Auto power off active
Low Battery Hold/Capture Value
Voltage Amperage
Ohms/Resistance Continuity
High Voltage Indication
Warning or Caution
Ground Dangerous Levels
Double Insulation
(Protection to Class II)
Safe for disconnect from
live conductors
CATEGORY DEFINITIONS
Measurement
Category
Short-Curcuit
(typical) kA
a
Location in the
building installation
II < 10 Circuits connected to mains socket
outlets and similar points in the MAINS
installation
III < 50 Mains distributions parts of the building
IV > 50 Source of the mains installation in the
building
OVERVIEW
A. Clamp: Measure inductive AC current. Opens to 0.76” (19.10mm).
B. Conductor Alignment Marks: Used to aid the visual alignment of a
conductor when measuring inductive amperage. Greatest accuracy is
achieved when the conductor inside the clamp is centered at the intersection
of these marks.
C. Category Max Indicator: Maximum CAT Rating for Clamp.
D. Hand Guide: Used as a point of reference for the operator’s safety.
E. Clamp Lever: Opens and closes current clamp. Do not allow fingers or objects
to become pinched in the clamp as it closes.
CAUTION: When sliding the clamp lever, be careful not to inadvertently
press any button when gripping the meter. That will place the meter in a
mode that was not desired.
F. Hold Button:
Press once to enable Hold. Press again to return to live readings.
Captures present value.
Press and hold the Hold button when meter is in Hold mode to disable
Auto power off mode. Press and hold again to enable Auto power off mode.
When powering on the meter using this button, the meter will default to
last mode used when meter was powered off.
G. Ohms/Continuity Button:
Ohms: Press to enter Ohms measurement mode.
Continuity: Press again to enter Continuity measurement mode.
AC Amps: Press again to enter AC Amps measurement mode.
H. AC/DC Volts Button:
AC Volts: Press to enter AC Volts measurement mode.
DC Volts: Press again to enter DC Volts measurement mode.
AC Amps: Press again to enter AC Amps measurement mode.
Press and hold to power off meter.
I. Display
J. Category Max Indicator: Maximum CAT Rating for test lead connections to
meter.
K. Test Leads: Permanent test leads.
Multifunction test lead used for measuring: AC or DC volts, Resistance
and Continuity.
L. Serial Number
M. Battery Cover: Easy access for replacing batteries.
N. Battery Cover Latches: Convenient, quick opening.
O. Test lead holders: For storing test leads when not in use.
S/N:
CATIII
600V
OPEN
LOCK
OPEN
LOCK
CATIII
600V
L
M
N
K
O
CAT III
600V
V
Ω
DL200
600V CAT III 200A
E
D
A
C
I
J
B
HOLD
F
G
H