CO95 Carbon Monoxide Detector INSTRUCTION MANUAL ENGLISH CO95 CARBON MONOXIDE DETECTOR 1-800-547-5740 • Fax: (503) 643-6322 www.ueitest.com • Email: info@ueitest.
TABLE OF CONTENTS Introduction ........................................................................................................................ 3 Safety............................................................................................................................... 3 Controls and Indicators .............................................................................................. 4 Operating Instructions...............................................................................
Introduction The CO95 is configured with a long-life CO sensor. The CO95 meter tests CO levels in heating appliances, ambient air, around fossil fueled appliances like cookers and grills. It also helps you test residential and commercial CO alarms and also shows CO MAX - the maximum level of CO measured. The CO95 can also be used as a digital thermometer, ideal for testing hot water or refrigeration.
Controls and Indicators 2 1 3 5 4 6 7 8 9 10 11 CO95 CARBON MONOXIDE DETECTOR 1. Power Push-button • Press “ “ button to switch the unit ON in fresh air outside the property about to be tested. This lets the meter auto calibrate its sensors properly. • When turned on the meter beeps four times and displays the top line date, time and model number.
2. UP/DOWN/ENTER buttons • Press the “DOWN” button for more than 1 second to change the displays top line. The rotary dial changes the displays bottom line. Example: The meter will display CO on its top line and temperature on its bottom line if you turn the rotary dial to “TEMP” and push the “DOWN” button until CO is displayed on the top line. • Use the “UP/DOWN/ENTER” keys to change settings (such as time and date) when the rotary dial is turned to “MENU”. 3.
11. BAT: Displays estimated battery life. • If battery voltage falls below a pre-set limit, the display flashes “LOW BAT.” every 10 seconds.
CFK1 – Optional Chemical Filter Kit (NOx Filter) CO sensors may respond to gases other than CO, resulting in slightly elevated readings. On low NOx equipment this impact will be very small, often less than the tolerance of your meter. If you anticipate high levels of SO2 or NOx, UEi recommends using our CFK1, in-line chemical filter. The CFK1 will remove NOx and SO2 from the gas sample, allowing a true view of the CO only.
After Using The Meter After using the meter to test appliances, remove it’s probe from the flue - IT WILL BE HOT - and let it cool. Do not put the probe in water which will be sucked into the meter, damaging its pump and sensors. When the meter readings return to ambient levels, turn the meter off. The meter counts down from 30 before switching off with the pump running to self-clean its sensors. Empty the water trap and check filter prior to storage and next use.
Maintenance Periodic Service WARNING! Repair and service of this instrument is to be performed by qualified personnel only. Improper repair or service could result in incorrect or erroneous reading from the meter. Perform only those maintenance tasks that you are qualified to do. These guidelines will help you attain long and reliable service from your meter: • • • • Calibrate your meter annually to ensure it meets original performance specifications Keep your meter dry.
Electromagnetic Compatibility (EMC) European Council Directive 89/336/EEC requires electronic equipment not to generate electromagnetic disturbances exceeding defined levels and have adequate immunity levels for normal operation. Specific standards applicable to this meter are stated below.
CO95 Carbon Monoxide Detector Limited Warranty The CO95 is warranted to be free from defects in materials and workmanship for a period of five years from the date of purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi’s option.