Safety NoteS
Before using this meter, read all safety information carefully. In this manual the word “WARNING” is used
to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used
to indicate conditions or actions that may damage this instrument.
WARNING!
This analyzer extracts combustion gases that may be toxic in relatively low concentrations. These gases are
exhausted from the back of the instrument. This instrument must only be used in well-ventilated locations.It
must only be used by trained and competent persons after due consideration of all the potential hazards.
C20 fuNCtioNS
•CarbonMonoxide(CO)Measuredinpartpermillion(ppm)
•CarbonDioxide(CO2)Measuredinpercentagevolume(%)
•COMAX-MaximumCOmeasured.
aNalyzer CoNNeCtioNS
WARNING!
Turning the pump off while the probe is in the flue will leave toxic
gases inside the analyzer. Once data has been read, it is advisable to
purge the unit with fresh air as soon as possible. To do this, with the
probe removed from the flue, turn ON the pump. Always allow the
readingstoreturntozero(00forCO)priortoshuttingtheunitoff.
WARNING!
The probe will be hot from flue gases. Remove the probe from the flue
andallowittocoolnaturally.Donotimmersetheprobeinwater,as
this will be drawn into the analyzer and damage the pump and sen-
sors. Once the probe is removed from the flue and the readings have
returned to ambient levels rotate the selector to “OFF”and switch off
theanalyzer.Theinstrumentwillcountdownfrom30toswitchoff.
C20 operatioNS
TheC20Combustionset-upmeterissuitableforusewithallcommondomesticfuelsincludingnaturalgas,
propane, butane and light oil.
NOTE:Alwaysbeginoperationinanareawithfreshair,freefromanyCOorCO2.
• PowertheC20onbyrotatingtheselectordialtoanyposition
• AllowtheC20tocompletecountdown
 • Rotateselectordialtodesiredparameterandbegintesting
WhennotmeasuringCOorCO2rotateselectorto“STANDBY”toextendbatterylife.
C20 CombuStioN Set-up meter typiCal uSeS
• Measureandverifymanufactureset-upvaluesforCO2andCOarewithinspecifiedrange.
• Checkforfluegasspillagearoundcapturehoods.
 • MeasurebackgroundandambientCOlevels.
OWNERS MANUAL & MAINTENANCE
1