Product Overview

WWW.UEITEST.COM USA 1.800.547.5740
CANADA 1.877.475.0648
TEMPERATURE MEASUREMENT
Parameter Range Resolution Accuracy
Flue temperature 32˚ to 1112˚F 0.1˚F +3.6˚F +0.3% rdg
Inlet temperature
(internal sensor)
32˚ to 112˚F 0.1˚F +1.8˚C +0.3% rdg
Inlet temperature
(external sensor)
32˚ to 1112˚F 0.1˚F +3.6˚F +0.3% rdg
FLUE GAS
Parameter Range Resolution Accuracy
Oxygen 0 to 21% 0.1% +0.3%
Carbon Monoxide
0 to 100ppm
1ppm
±5ppm
100 to 400ppm ±20ppm
400 to 2,000ppm ±5%
2,000 to 9,999ppm ±10%
Above 10,000ppm purge
pump operates
Unspecified
Carbon Dioxide 0 to 20% 0.1% 0.3% volume
Efficiency (Net or Gross) 0 to 99.9% 0.1% +1.0% rdg
Efficiency High (C) 0 to 119.9% 0.1% +1.0% rdg
Excess Air 0 to 250% 0.1% +0.2% rdg
CO/CO2 ratio 0 to 0.999% 0.0001 +5% rdg
PRESSURE (DIFFERENTIAL)
Parameter Range Resolution Accuracy
Normal range ±80mbar
maximum over range without
damage is ±400mbar
±0.08" WC
(+0.2mbar)
Maximum
0.001" WC <9.9999" WC
0.001" WC >10.00" WC
(0.001mbar <24.99mbar)
(00.1mbar >25mbar)
±0.0002" WC
(±0.005mbar)
±0.4" WC (±1mbar)
±0.01" WC
(±0.03mbar)
±32"WC (±80mbar) ±0.3%
PRE-PROGRAMMED FUELS
Natural Gas, Propane, Butane, LPG, Light Oils (28/35sec), Wood Pellets, Town Gas, Coke
Gas, Bio Oil, Bio Gas
USER PROGRAMMED FUELS 5 User defined fuels
STORAGE CAPACITY 30 tests
Made in UNITED
KINGDOM
Specifications
Downloads
Manual
Data Sheet
Copyright ©2021 Kane USA Inc. All Rights Reserved.
IOS
®
and Android™ are property of their respective owners. L717
Residential/Commercial Combustion
Analyzer Kit w/ Printer
C165+KIT