Install Instructions
6
The C165+ Combustion Analyzer measures CO, CO2, differential temperature and differential pressure.
CO2 is set to zero in fresh air automatically after the initial countdown.
It is important that re-zeroing is done in outside fresh air as indoor CO2 levels are affected by human breath.
It calculates oxygen (O2), CO/CO2 ratio, Losses, Combustion Efficiency (Gross, Nett, Gross Condensing, or Nett Condensing).
The C165+ Combustion Analyzer can also measure CO levels in ambient air - useful when a CO Alarm is triggered. It can also perform a Room CO Test
for 30 minute duration.
A low flow detection system warns of low flow and switches the pump off. This also helps to prevent water ingress from overfilled water traps.
The analyzer has a protective rubber boot with magnets for hands-free operation and is supplied with a probe with an integral temperature sensor.
A large 6 line display provides the user with relevant information. All data can be printed via the infrared printer or Wireless Printer App.
The C165+ uses a new data storage system allowing the user to store the maximum number of logs of interest to them, rather than be restricted to
an allowance of particular logs.
The memory can store up to 45 logs of any combination of Combustion, AUX, Temperature, Heat Exchange, Room CO.
OVERVIEW