Install Instructions

2
FUNCTIONS
FEATURES
Flue temperature: 32° to 1112°F
Inlet temperature: Internal/ External sensor 32° to 112°F
O2: 0 - 21%
CO: 2000 ppm
CO2: 0 - 20 %
Efficiency: Nett/Gross 99.9%
Efficiency: High (calculated) 119.9%
Excess air: 250%
CO/CO2 ratio: 0.99%
Differential pressure
TABLE OF CONTENTS
Functions .............................................2
Features ..............................................2
General Specifications ................................3
Important Safety Warnings ............................3
Symbols ..............................................4
Analyzer Overview ..................................4-5
Overview
...........................................6
Pre Test Checklist
...................................7
Setting Inlet Temperature
...........................7
Analyzer Connections
...............................7
Emptying & Cleaning the In-Line Water Trap
........7
Changing The Particle Filter
.........................7
Quick Start
..........................................7
Fresh Air Purge
......................................8
CO Over-range Protection Pump
.....................8
Measuring Flue Gases
...............................8
Using The Menu
..................................9-11
Combustion Test
................................. 11-12
- Optional Nitric Oxide Sensor
.....................12
Heat Exchange Integrity Test
.......................13
Room CO Test
......................................13
Printing
............................................14
Printouts
...........................................14
iOS App Guide
.....................................15
Kane Wireless Printer App Home iOS Screen ............15
Kane Wireless Printer App Settings Screen .............15
Android App Guide
.................................16
Kane Wireless Printer App Home Android Screen ........16
Kane Wireless Printer App Android Settings Screen ......16
Kane Wireless Printer App Android Personal
Details Screen .....................................16
Temperature Testing
...............................17
Pressure/Temperature Testing
......................17
Pressure Measurement Good Practice
..............17
Large Bore Tubing Issues
...........................17
Analyzer Specification
..........................18-19
Certification
........................................19
Electromagnetic Compatibility
......................19
Where To Test
...................................20-21
What Results Are Generally Acceptable
............21
Powering Off
.......................................22
Post Test
...........................................22
General Maintenance
..............................22
Cold Weather Precautions
..........................22
Replacing The Batteries
............................23
Annual Recertification
.............................23
Recertification Services
............................24
Returning Your Analyzer
............................24
Where To Send Your Analyzer
......................24
Other Important Factors Relating To Combustion
...25
Combustion Measurement Terms
...................25
Disposal
............................................26
Storage
.............................................26
End Of Life Disposal
................................26
Warranty
...........................................26
EOS Technology
Pre-programmed fuels: Nat Gas, H Oil, Pellets, L Oil, LPG,
Butane, Propane
Memory Positions: 45
6 line backlit display
High altitude compensation
User customizable parameter views
Individual report printouts
Real-time clock