Product Overview

WWW.UEITEST.COM USA 1.800.547.5740
CANADA 1.877.475.0648
Temperature Measurement
Parameter Range Resolution Accuracy
Flue Temperature 32˚ to 1112˚F (0˚ to 600˚) 0.1˚F (0.1˚C) ±1.0˚F (0.5˚C)
Inlet Temperature (Internal Sensor) 0.1˚F (0.1˚C) ±2˚F (1˚C)
Inlet Temperature (External Sensor) 32˚ to 1112˚F (0˚ to 600˚) 0.1˚F (0.1˚C) ±1.0˚F (0.5˚C)
Flue Gas Measurement
Parameter Range Resolution Accuracy
Carbon Monoxide 0 to 2000 ppm 1 ppm ±3 ppm or ±5% rdg (whichever
is greater)
(Optional H2 Compensated) 2000 to 10000 ppm 1 ppm ±10% rdg
Carbon Dioxide 0 to 20% 0.1% ±0.3% volume
Calculations
Parameter Range Resolution Accuracy
Oxygen 0 to 21% 0.1% ±0.3% volume
Efficiency (Net or Gross) 0 to 99.9% 0.1% ±1% rdg
Excess Air 0 to 119.9% 0.1% ±0.2% rdg
Specifications
Copyright ©2021 Kane USA Inc. All Rights Reserved.
Pre- Programmed Fuels Natural Gas, Propane, LPG, Light Oil, Heavy Oil, Bio Oil, Pellets
Battery Life >8 hours (continuous with pump on)
Certification The C161 is TUV-tested and certified to EN 50379, Parts 1-3 in accordance
to 1st German Federal Emission Control Ordinance (BimSchV)
Operating Conditions
Temperature 32˚ to 113˚F (0˚ to 45˚C)
Humidity 15% to 90% R.H.
Storage Temperature 0˚ to 113˚F (-18˚ to 50˚C)
Power Supply Rechargeable Batteries, USB Charging
Dimensions
Dimensions 8.54" x 4.18" x 1.86"
Weight 1 lb., 5.1 oz.
Residential Combustion Analyzer
C161
0 53533 50833 8
Made in UNITED
KINGDOM
Downloads
Manual
Data Sheet