C161 Quick Start Guide BACKED BY O2/Eff CO/CO2 Temp Exch Test Aux Status O2 TE MP v3 C161 Com busti o n An CO C er alyz 1-800-547-5740 • Fax: (503) 643-6322 www.ueitest.com • Email: info@ueitest.
C161 OVERVIEW Power button Display lines 1 through 6 Protective boot with built-in magnets Status bar line Navigation Log & Print O2/Eff CO/CO2 Temperature screen Temp Exch Test Aux Status v3 O2 TE MP Pump CO/CO2 screens O2/Eff screens Auxiliary screen Status screen Menu screen C161 Com busti o n An CO er alyz C LED Water Trap Full Indication Water Trap Window K-type temperature inputs USB charging port T2 T1 Combustion hose input Water trap drain plug
MENU SCREEN - C161 START UP Press ”Power” Button for 2 seconds. The analyzer will perform a 60 second purge. This should be done in fresh air. Rotate Selector Dial to MENU to set up or customize your settings. Selected parameter are centered, highlighted with arrow icons on either side. Use Press and buttons to scroll menu options, to select and edit a parameter. O2/Eff CO/CO2 Temp Exch Test Aux Press and buttons to change contents of a field. Status Press button to scroll fields.
BEFORE TESTING CHECKLIST o Clean particle filter o Water trap and probe line are free of water o All hose and thermocouple connections are properly secured o Water trap is fitted correctly o Power on and zero o Flue gas probe is sampling ambient FRESH air Remove the rubber boot and red drain plug. Allow the water to drain out. Re-insert the rubber plug and replace boot cover. Remove protective rubber boot. Remove water trap from analyzer. Remove particle filter from spigot and replace with new one.
CHANGE FUEL TYPE O2/Eff CO/CO2 Temp Exch Test Aux Status O2 TE MP v3 C CO r X Press and buttons to scroll fuel selections. Press to select fuel. 1 1 AU AU X STA TUS AUXILIARY SCREEN O2/Eff CO/CO2 2 CO C161 Com busti CO CO 2 TE MP STA TUS E FLU E FLU Press button until the Fuel Type displays on the Status Bar. Press and Hold until two arrow icons display. FLUE 2 FLUE 2 Rotate the dial to either AUX, O2/Eff, CO/CO2 or TEMP setting.
yze X 2 CO CO o n A n al TEM P TEM TE MP 2 CO C161 Com busti AU STA TUS TE MP P TEM TE MP 2 CO r To Log: During testing, Press and to log a report. Hold To view these Logs, see View Saved Logs section. E1 yze X FLU CO o n A n al AU STA TUS FLUE 2 C161 Com busti During testing, Press to start printing. Press again to abort. E1 X FLU 1 AU STA TUS FLUE 2 FLUE FLUE 2 To Print: Align printer (sold separately) above Analyzer.
POST TESTING POWERING OFF When you power off the C161, there is a 10 second purge. CAUTION Remove the probe from the flue and allow analyzer to purge with fresh air until readings return to zero. O2 to 20.9%, CO to Zero CAUTION: probe tip will be HOT. Make sure you do not exceed the analyzer’s operating specifications.
ANNUAL RECERTIFICATION SERVICES Complete care for your C160 series combustion analyzer. When you: Request Recertification or Service Online Within 1 Year of Purchase or Service UEi will: 6-Year Warranty: All UEi combustion analyzers have a standard 1-year warranty. Each recertification includes a 30-point inspection and extends the warranty for 1 more year for up to 6 years from the date of warranty. Contractors who book recertification of a C160 series analyzer at www.ueitest.