User Guide
EAGLE X: FEATURES & SPECIFICATIONS
................................
Measures
• CO2 (EOS T
echnology)
• CO (Long Life Sensor)
• Inlet Temp/Flue Temp
• Hi-Res Differential Manometer (select 0.01”/0.001”wc)
• NO (EAGLE 3X: installed, EAGLE 2X: available as upgrade)
Calculates
• O2
• Net T
emp
• Efficiency
• Excess Air
• Differential Temp (T1-T2)
• Differential Pressure (P1-P2)
PreProgrammed Fuels
• Natural Gas
• Propane
• Heavy Oil
• Light Oil
• Bio Fuel
• W
ood
Features
• Gas Zero
†
• High level CO alarm
• CO data logger
• Heat exchanger test
• Worklight
• 4 line backlit LCD display
• 179 memory positions
• User customizable auxiliary screen
• User programmable headers
• Individual report printouts
• Time and date stamp
• Rotary style selector
• Protective boot w/integral magnet
• Real time clock
• CO readings as low as 1 ppm
• Infrared printer port
• Low battery indicator
• Field replaceable sensors (USA ONLY)
• 5 year limited warranty (including sensor)
NEW! Ô
NEW! Ô
NEW! Ô
NEW! Ô
NEW! Ô
NEW! Ô
NEW! Ô
NEW! Ô
Temperature EAGLE X: C155 & C157
Flue Temp Range 20~2400°F (-29~1315°C)
Inlet Temperature (probe - T2) 20~2400°F (-29~1315°C)
Inlet Temperature (ambient) 32~112°F (0~50°C)
Net Temperature (∆T)** 20~2400°F (-29~1315°C)
Resolution 0.1°C/F
Flue (T1, Inlet T2 & ∆T) Accuracy ±(0.3% rdg +3.6°F(2°C))
Inlet Temperature Accuracy ±(0.3% rdg +1.8°F(1°C))
Pressure EAGLE X: C155 & C157
Range Accuracy
±0.08” wc (±0.2mBar) 2±0.002” wc (±0.005mBar)
±0.4” wc (±1mBar) ±0.01” wc (±0.03mBar)
±32” wc (±80mBar) ±3% rdg
Resolution 0.001” wc < 9.999” wc
0.01” wc >10.00” wc
0.001mBar<24.999mBar
0.01mBar > 25 mBar
Gas EAGLE X: C155 & C157
Oxygen 0~21%**
O2 resolution / accuracy 0.1% / ±0.3%
Carbon Monoxide (CO) 0~2000 ppm
(4000 max 15 min)*
CO resolution / accuracy 1 ppm / ±10 ppm<100ppm,
±5% rdg>100ppm
Carbon Dioxide (CO2) 0~20%*
CO2 resolution / accuracy 0.1% / ±2%
Efficiency** 0~99.9%**
Efficiency resolution/accuracy 0.1% / ±3%
Excess Air** 0~250%**
Excess Air resolution/accuracy 0.1% / ±3%
CO/CO2 ratio** 0~0.999
CO/CO2 resolution/accuracy 0.001 / ± 5% rdg
Nitric Oxide (NO1)*** 0~100 ppm
NO1 resolution/accuracy*** ±2 ppm <30ppm
±5ppm <100ppm
* Measured at STP (standard temperature and pressure)
** Calculated value
*** NO1 sensor installed on C157. Available as an upgrade for C155.
†
Gas Zero (Fresh Air Zero) - Is a reset procedure to maintain accurate readings
from the EOS sensor. This procedure compensates for any change in ambient
conditions that may impact the readings.