User Guide

LOWEST COST OF OWNERSHIP
NO O2 SENSOR:
The new
E
E
a
a
g
g
l
l
e
e
X
X
Combustion & System Analyzers
e
e
l
l
i
i
m
m
i
i
n
n
a
a
t
t
e
e
s
s
the number one
hassle experienced by HV
AC contractors, the
a
a
n
n
n
n
u
u
a
a
l
l
c
c
o
o
s
s
t
t
and down time of
r
r
e
e
p
p
l
l
a
a
c
c
i
i
n
n
g
g
t
t
h
h
e
e
O
O
2
2
s
s
e
e
n
n
s
s
o
o
r
r
. This new technology for combustion analysis replaces the everyday
electro-chemical O2 sensor with the EOS T
echnology™ CO2 sensor,
l
l
o
o
w
w
e
e
r
r
i
i
n
n
g
g
t
t
h
h
e
e
c
c
o
o
s
s
t
t
o
o
f
f
o
o
w
w
n
n
e
e
r
r
s
s
h
h
i
i
p
p
.
.
EOS TECHNOLOGY:
The
n
n
e
e
w
w
E
E
O
O
S
S
CO2 sensor takes
d
d
i
i
r
r
e
e
c
c
t
t
C
C
O
O
2
2
m
m
e
e
a
a
s
s
u
u
r
r
e
e
m
m
e
e
n
n
t
t
s
s
and calculates the O2 level.
This CO2 sensor has no physical contact with the gas, so there is
n
n
o
o
d
d
e
e
t
t
e
e
r
r
i
i
o
o
r
r
a
a
t
t
i
i
o
o
n
n
of the
sensor
o
o
v
v
e
e
r
r
t
t
i
i
m
m
e
e
. This exclusive EOS sensor has a
5
5
y
y
e
e
a
a
r
r
l
l
i
i
m
m
i
i
t
t
e
e
d
d
w
w
a
a
r
r
r
r
a
a
n
n
t
t
y
y
and an
unmatched industry-leading life expectancy of 10 years!
NEW EOS VS Electro-Chemical Sensors:
In an electro-chemical sensor, the gas measured passes into the sensor to an electrode
where it produces a chemical reaction generating a current. The amount of current created
is relative to the level of gas detected.
This process eventually wears down the sensor causing accuracy to drift and eventually
losing all current output all together. Any mathematical calculations based on these meas-
ured levels will also drift accordingly
. The typical industry standard life span of these sensors
is between one to two years pending use.
In the Electro-Optical Sensor, or EOS Technology™, the gas flows between an Infrared
transmitter and a receiver. The receiver detects the gas particles and communicates the
level as a result. The advantage to this process is there are no parts to wear down and
no physical cause for accuracy drifting. This benefits all calculations that are based on the
measured value by maintaining a longer and higher level of accuracy.
Xtended LIFE CO SENSOR:
The
E
E
a
a
g
g
l
l
e
e
X
X
also offers a
n
n
e
e
w
w
X
X
t
t
e
e
n
n
d
d
e
e
d
d
L
L
i
i
f
f
e
e
C
C
O
O
S
S
e
e
n
n
s
s
o
o
r
r
, which has a life expectancy of
5 years and is backed by a
5
5
y
y
e
e
a
a
r
r
l
l
i
i
m
m
i
i
t
t
e
e
d
d
w
w
a
a
r
r
r
r
a
a
n
n
t
t
y
y
. Reducing the sensor’s replacement
frequency helps to
m
m
i
i
n
n
i
i
m
m
i
i
z
z
e
e
the analyzer’s
c
c
o
o
s
s
t
t
o
o
f
f
o
o
w
w
n
n
e
e
r
r
s
s
h
h
i
i
p
p
to just the CO sensor calibra-
tion. Most manufacturers recommend annual calibration to maintain sensor specifications.
EAGLE X: AT A GLANCE
................................