Brochure
19
Customize the KM940 or select one already suited to fit your needs
Functions
Measures:
• Oxygen (O2): 0 ~ 21%
• Carbon monoxide (CO): 0 ~ 10,000 ppm
(H2 Compensated)
• Pressure
• Flue temperature: 0°~1112°F
Calculates:
• Efficiency: 0 ~ 99.9%
• Carbon dioxide (CO2): 0 ~ 99.9%
• Losses: 0~99.9%
• Excess air: 0 ~ infinite
• CO/CO2: 0 ~ 0.999
• Poison index: 0 ~ 99.9%
• Net temperature differential
Customizable:
• Add 2 toxic gas sensors in
addition to installed O2 and CO sensors
Preprogrammed Fuels:
Natural Gas, Butane, Light Oil, Heavy
Oil, Coal, Coke, Propane, Anthracite,
LP Gas, Town Gas, Natural Gas2,
Gas Core, and 1 user defined fuels
Features
• Multiple line display
• Infrared printer port
• 150 test memory slots
• 1 Year limited warranty
Optional Sensors Part#
NO1
1
13251
NO2
1
10533
SO2
1
13910
Includes
Flue Probe KMCP10
Pressure sensor KMPS4
Replacement particle filter 16345
AC Adapter / charger KMCU900/110
Water trap assembly WT900/2
Large cordura case
Manual
KM900PLUS
INDUSTRIAL COMBUSTION ANALYZER
Functions
Measures:
• Oxygen (O2): 0 ~ 21%
• Pressure
• Flue temperature: 0° ~ 1112°F
Calculates:
• Efficiency: 0 ~ 99.9%
• Carbon dioxide (CO2) 0 ~ 99.9%
• Losses: 0 ~ 99.9%
• Excess air: 0 ~ infinite
• CO/CO2: 0 ~ 0.999
• Poison index: 0 ~ 99.9%
• Net temperature differential
Customizable:
• Add 2 toxic gas sensors in
addition to installed O2
Preprogrammed Fuels:
Natural Gas, Butane, Light Oil, Heavy
Oil, Coal, Coke, Propane, Anthracite,
LP Gas, Town Gas, Natural Gas2,
Gas Core, and 1 user defined fuel
Features
• High suction double-headed pump
• Multiple line display
• Infrared printer port
• 150 test memory slots
• 1 Year limited warranty
Optional Sensors Part#
CO (H2 Compensated)
1
12933
CO High Range
1, 2
13911
NO1
1
13251
NO2
1
10533
SO2
1
13910
Includes
Flue Probe KMCP10
Pressure sensor KMPS4
Replacement particle filter 16345
AC adapter / charger KMCU900/110
Water trap assembly WT900/2
Large cordura case
Manual
KM940
INDUSTRIAL COMBUSTION ANALYZER
Industrial analyzers
Accessories/Options
Thermal printer - IR Link KMIRP2
CO Sensor: 0 ~ 10,000 ppm
H2 compensated
1
12933
CO Sensor: (KM940 Only)
High range 0 ~ 10%
2
13911
NO Sensor: 0 ~ 5,000 ppm
1
13251
NO Sensor: low range
0 ~ 100 ppm
1
18079
NO2 Sensor:
0 ~ 1,000 ppm
1
10533
SO2 Sensor: 0 ~ 5,000 ppm
1, 2
13910
SO2 Sensor: low range
0 ~ 100 ppm)
1
18131
Replacement Parts/Supplies
Flue probe KMCP10
Thermal paper for KMIRP2 16646
Smoke pump SPT1
Smoke paper and chart SP9
Particle filter 16345
Battery 16486
AC Adapter / charger KMCU900/110
AC Adapter power cord PSL/US
Water trap (case mount) WT900/2
O2 Sensor OS12
Pressure sensor (differential)
1
KMPS4
Fireworks reporter software KMFR1
KM9 SERIES
ACCESSORIES & REPLACEMENT PARTS
1
KM940 and KM900PLUS sensors are factory replacement and calibration only and are not eligible for user or in-field service.
2
Special Order ONLY
Customize the KM900 or select one already suited to fit your needs
Item Description UPC
KM900CON KM900Plus with NO1 Sensor (Calculated Total NOx) 05353350672
KM900CONOX KM900Plus with NO1/NO2 (True Total NOx) 05353350673
KM900CONS KM900PLUS with NO1 and SO2 (Calculated Total NOx) 05353350674
KM900COS KM900PLUS with SO2 05353350675
Item Description UPC
KM940CO KM940 with CO (0~10,000ppm), H2 Compensated 05353350684
KM940CON KM940 w/CO and NO1 (Calculated Total NOx) 05353350661
KM940CONOX KM940 w/CO, NO1 and NO2 (True Total NOx) 05353350663
KM940CONS KM940 w/CO, NO1 and SO2 (Calculated Total NOx) 05353350664
KM940COS KM940 w/CO and SO2 05353350662
KM940CO% KM940 with High Range CO (0~4%) 05353350665