Manual

4
Features and Use
General
The unit performs the following tasks:
Sense and display pressures present in the manifold
Calculate and display dew / bubble points corresponding to the
sensed pressures, for the selected refrigerant
Sense and display temperature of probe tip
Calculate and display system superheat or subcooling, based on
sensed pressure and temperature, for the selected refrigerant
Displays maximum and minimum pressures observed since
threshold reset
The unit has two 1/8" pressure ports, acting as two gauges: blue for
low side, red for high side. All settings are controlled through the
keypad and affect both sides of the display.
Some features of the unit include:
Working pressure ranges:
Low side: 0-200psia (1350 kPa, 13.5 bar)
High side: 0-550psia (3000 kPa, 37.9 bar)
Sensing resolution (precision):
Low side: 0.25psi or 0.4"Hg (2kPa, 0.02 bar)
High side: 1psi (7 kPa, 0.07bar)