Owners Manual
Table Of Contents
94
Problem occurrence and
question
9.1 Power
Power is not turned on by pressing .
Check whether the screen is turned off with the switch being pressed
for about 1 second.
Cannot continue splicing after several times of splices even with the
fully charged battery.
Power is quickly consumed when “Save mode” is not in use. Refer to
the [Save Mode] and supply the power appropriately at all times.
When the battery is not used for excessively long period time,
recharge it.
If the battery’s life ends for long-term use, replace it with a new one.
As the battery operates using chemical reaction, its wattage drops
with low temperature and it rapidly drops particularly with
temperatures below zero. As the splice current consumption goes up
with high temperature, battery’s power consumption accelerates.
LED is not turned on upon charging.
Disconnect the charter’s AC power cord and connect the DC cord to
the charging jack.
Connect the AC power cord after 10~15 seconds. Then the battery’s
LED is turned on red and charging starts.
Remaining battery is not indicated.