Splicing problem solving
8.1 When loss is high
Any dust or foreign substance on the fiber surface may incur poor splice.
Clean the fiber surface sufficiently.
Do not clean the fiber after cleaving to prevent dust from being
gathered on the fiber cross section.
Do not push in the fiber when putting it on V-Groove.
The fiber should be placed from the top to bottom.
Any foreign substance on V-Groove hinders the correct alignment.
Keep the V-Groove clean at all times.
Electrodes bad condition
When an electrodes contains an abrasion or its tip is bent and dirty,
replace the electrodes.
Arc amount and arc time are inappropriate.
Check the setting of arc amount and arc time to reset them with
proper values.
Without any great change, the initially set values are the most
appropriate ones.
Inappropriate splice mode
Check whether appropriate splice mode is selected for the fiber.