Owners Manual

53
Arc2 Power
[Arc2 Power] is the second level of arc.
[Arc2 Power] is set in this area.
Arc2 Time
It sets the time for [Arc2 Power].
Uneditab
le
Editable
It sets the time for [Arc2 Power]. [Arc time
2] is generally set as “OFF.”
It can set the arc time as a very long time
period but when [Arc1 Time] and [Arc2
Time] exceed 30 seconds, the electrodes
can be damaged.
Arc2 On - Time
While [Arc2 Power] is on arc, you can set
the arc amount as “ON” and “OFF” in turn.
The time period for [Arc2 Power] being
“On” is set in this area. For re-arc, set the
arc time as “ON” at all times.
Arc2 Off - Time
It sets the time period for the arc of [Arc2
Power] when it is turned off.
When [Arc2 Power] is occasionally stopped,
re-arc can also be stopped. When re-arc is
continuously required, set as to “OFF.”
Rearc Time
It sets re-arc time.
Editable
Within [splice mode edition], it
automatically sets to arc the re-arc
amount with the same intensity as that of
[Arc2 Power].
If [Arc2 Power] is set as ON/OFF, re-arc is
automatically changed.
Taper Splice Off
When the fiber is made thin, the splice loss
is sometimes increased. This pulling
function is set to “OFF.” The following 3
parameters decide the pulling shape.
Unedieta
ble