Owners Manual

52
Gap set Pos
It sets location of fiber spliced at the
center of arc.
Uneditab
le
When MFD of both fibers differs, do the
sealing procedure by melting the smaller
MFD fiber more than the bigger MFD fiber.
To heat the smaller MFD fiber more, splice
loss can be lowered by moving the
clearance location toward the bigger MFD
fiber at the center of arc.
Prefuse Power
It sets initial arc amount from the
beginning of arc before the fiber is
advanced. If the value of initial arc amount
is too low, the angle of the fiber cross
section is poor and consequently, an offset
can be incurred on the axis if it is too high,
the fiber can made round or burnt too
much and, consequently, the splice loss
value can be big.
Prefuse time
It sets the initial time from the beginning
of the arc before the fiber advance. If
[Prefuse time] is long, it means the same
that [initial arc amount] gets big.
Overlap
It sets the duplication of the fiber on for
the fiber advance amount.
If [Prefuse Power] is weak or [Prefuse
time] is short, set the [overlap] to
somewhat small and if the arc amount is
strong and the time is long, set it to
somewhat big.
Arc1 Power
Main arc can be adjusted by 2 levels.
The first level of arc is [Arc1 Power] and
the second is [Arc2 Power]. [Arc1 Power]
is set in this area.
Arc1 Time It sets the time for [Arc1 Power].