User's Manual

Digital UHF Transmitter Chapter 2, System Description and
Customer Remote Connections
DT835A, Rev. 1 2-12
Figure 2-2: Amplifier Array Remote Interface Panel
Amplifier Array Assembly Remote Metering
(A1) UHF Amp Tray Refl Pwr J5-2
(A1) Reflected Power Rtn J5-1
1V full scale at 1k source
resistance
(A1) UHF Amp Tray Fwrd Pwr J5-4
(A1) Forward Power Rtn J5-3
1V full scale at 1k source
resistance
(A2) UHF Amp Tray Refl Pwr J5-6
(A2) Reflected Power Rtn J5-5
1V full scale at 1k source
resistance
(A2) UHF Amp Tray Fwrd Pwr J5-8
(A2) Forward Power Rtn J5-7
1V full scale at 1k source
resistance
(A3) UHF Amp Tray Refl Pwr J5-9
(A3) Reflected Power Rtn J5-10
1V full scale at 1k source
resistance
(A3) UHF Amp Tray Fwrd Pwr J5-11
(A3) Forward Power Rtn J5-12
1V full scale at 1k source
resistance
(A4) UHF Amp Tray Fwrd Pwr J5-13
(A4) Forward Power Rtn J5-14
1V full scale at 1k source
resistance
(A4) UHF Amp Tray Refl Pwr J5-15
(A4) Reflected Power Rtn J5-16
1V full scale at 1k source
resistance
(A5) UHF Amp Tray Fwrd Pwr J5-18
(A5) Forward Power Rtn J5-17
1V full scale at 1k source
resistance
(A5) UHF Amp Tray Refl Pwr J5-21
(A5) Reflected Power Rtn J5-20
1V full scale at 1k source
resistance
The above connections are made to jack (J5), the 37-position “D” connector on
(A11) the remote interface panel (Figure 2-2) mounted at the top, rear of each of
the amplifier array cabinets.