User's Manual
Innovator CU250ATD, 250 Watt Transmitter Tray Description
Instruction Manual, Rev. 0 15
Signal Name
J5 Pin
Designations
Signal Type/Description
RMT RF System
Interlock
5
When this signal's circuit is completed to ground, the
transmitter is allowed to operate. If this circuit is
opened, the transmitter switches to Standby.
RMT
Reflected Power
6
Analog Output - 0 to 4.0 V- This is a buffered loop
through of the calibrated “System Reflected Power ”.
Indicates the transmitter's Reflected power. Scale
factor is 100 % / 3.2V.
RMT
Fault Reset
7
Discrete Open Collector Input - A pull down to
ground on this line indicates that any transmitter
Faults are to be reset.
RMT
Operate Status
11
Discrete Open Collector Output - A low indicates that
the Transmitter is in Operate.
RMT
Fault
13
Discrete Open Collector Output - A low indicates that
the Transmitter has a Fault.
RMT
Input Fault
15
Discrete Open Collector Output - A low indicates that
the Transmitter has an Input Fault.
Not Used 16 N/A