User's Manual
Digital ATSC Exciter-Modulator System Chapter 2,
Installation and Operating Instructions
Axcera Axciter, Rev. 0 39
Setup Screen
Debug Level
This value shows the Current Debug level of the Fox Control Software.
During normal operation this value will be set to zero (0). However, if
problems are encountered this number can be adjusted to add information to
the log file. To change the level use command one (1). Valid debug levels
range from zero (0) to three(3).
Adaptive SNR Threshold
This value shows the Current Signal to Noise Ratio Threshold. When
Adaptive SNR reaches this level it no longer changes the equalizers. To
change the Threshold use command number two (2) and enter a value
between 25 and 50.
Axact Good Files
This shows the number of “good” files that AXACT produces. These are
debug log files. The good files have AXACT information in them. To change
this value select command three (3) and enter a value between 0 and 99.