User's Manual

Innovator CU0TD-1/CU0RD-1 – CU4TD/CU4RD Initial On Site
ATSC Transmitter/Regenerative Translator Turn On Procedure
Instruction Manual, Rev. 1 42
Table 11B: Enter Key Sets to Change Mode Screen (TD/RD)
This screen informs the operator that to make changes, the Enter key or the Right key
must be pushed, which will cause the display that can be changed to blink. Use the up
or down key to change the display and the left or right key to move the blinking item on
the display. After changes are made in the Set Up Menus pushing the enter Key,
Button, will accept the changes made. With the Right Key Sets To Change Mode screen
displayed, pushing the ENTER button will access the first main submenu under the Set
Up main menu, which is the Chassis Values Set Up Menu.
Table 11.1: Chassis Values Main Set Up Menu Screen (TD/RD)
This is the System Set Up Chassis Values Main Sub Screen. Push the ENTER button
to access the Chassis Values submenus or push the DOWN Arrow to view the next
Set Up Main Sub Screen, which is the Set Up 8VSB Demodulator Main Sub Screen.
NOTE: Refer to the description in Table 11B for how to change the values on the
following set-up screens.
Table 11.1.1: Chassis Values Forward Power Set Up Screen (TD/RD)
Remote or front panel adjustment of the output power of the transmitter.
The bar graph indicates the range remaining in the adjustment.
NOTE: If the transmitter's output power is being adjusted through the web
page, the transmitter's forward power will be blinking on this screen. It will
remain blinking while the transmitter is adjusting to the desired target power
level.
Table 11.1.2: Chassis Values Model Number Set Up Screen (TD/RD)
This screen allows the set up of the Model Number of the
transmitter/regenerative translator. This causes the system to access the
proper parameters to be displayed on the LCD screens. NOTE: Do not
change this screen without first consulting with Axcera.
Table 11.1.3: Chassis Values Jump to Menu on Fault Set Up Screen (TD/RD)
The 'Jump To Menu' setting screen allows an operator to change how the
transmitter's display system works. When this value is set 'ON' and a new
fault occurs, the transmitter will automatically change the display screen to
show the new fault condition. When this value is set 'OFF', the display screen
does not change when a new fault is detected.