User's Manual

Innovator CU0TD-1/CU0RD-1 – CU4TD/CU4RD ATSC Initial On Site
Transmitter/Regenerative Translator Turn On Procedure
Instruction Manual, Rev. 2 82
Initial On Site Turn-On Procedure
After the Innovator CX Series drawer or drawers are installed and all input, output and AC
connections are made, the system is ready for the initial on site turn on. Check that the
output of the transmitter is connected to an appropriate rated load or to the digital mask
filter and the antenna for your system. Check that the main AC power to the System is ON.
If your system contains an optional ASI to S310 converter module, K-Tech receiver drawer
or Axciter, check that they have AC connected to them and that they are turned ON.
NOTE: If your system is mounted in a cabinet and contains an optional UPS, check that the
ON/OFF button, located on the left side of the top panel of the UPS is On. The UPS is
normally mounted behind the removable blank panel, located immediately above the
exciter/driver drawer, which is held in place by four #10 Phillips head screws.
Single or Multi Drawer Systems
If you have a CU0TD-1 thru CU0TD-5 system, push ON the switch located on the rear panel
of the drawer above the AC power jack. The large fan mounted on the rear panel of the
drawer should operate.
If your system is a CU1TD/TD-1 or higher power system, switch ON the ON/OFF circuit
breaker(s), located on the rear panel of the amplifier drawer(s), mounted on each side of the
AC input power jack. The two fans mounted in the amplifier drawer should operate.
Place the system in Operate. The Operate/Standby LED and Status LEDs on the CU0TD-1
thru CU0TD-5 should be Green indicating the system is in Operate and performing normally.
The Operate/Standby LED showing Amber indicates the System is in Standby. The Status
LED showing a blinking Red LED indicates an Event (Fault) is occurring now. The Status LED
showing Amber indicates that an Event (Fault) occurred since the last time the Event (Fault)
indications were reset. NOTE: The modulator takes approximately 2 minutes to lock up for
normal operation. During this time the modulator status screen will blink warm up.
If your system is CU1TD/RD-1 or higher power, the Enable LED and Status LEDs on the
Amplifier Drawer should be Green indicating the system is in Operate and performing
normally. The Enable LED showing Amber indicates the System is in Standby. The Status
LED should be Green indicating no Events (Faults) in the system. If the Operate/Standby LED
shows Amber it indicates that the System is in Standby. If the Status LED is blinking Red it
indicates an Event (Fault) is occurring now. If the Status LED shows Amber it indicates that
an Event (Fault) occurred since that last time the Event (Fault) indications were reset. The
output power is factory set according to customer request and does not need adjusted. If a
problem occurs, call UBS-Axcera field support at 724-873-8100 for information on modifying
the power level of the system.
Once the modulator has finished its boot up process it can be configured for LAN access.
Using the Web GUI, navigate to the System parameters sub-menu where the Network
parameters can be configured. After changing any Network parameters, the modulator
must be reset. Navigate to the System parameters sub-menu System Reset page to reset
the modulator. The modulator can now be provisioned remotely through the Web GUI.