User's Manual

Innovator CU0TD-1/CU0RD-1 – CU4TD/CU4RD 8VSB ATSC Modulator
ATSC Transmitter/Regenerative Translator
Instruction Manual, Rev. 2 70
Using the Ethernet Port to Access the CLI
The modulator can be connected directly to a laptop PC or through a hub/switch using
an RJ-45 straight-through cable.
The modulator and laptop PC must be configured to be on the same IP network so that a
connection can be established.
A Telnet client can be opened from the “Start/Run” button on the laptop PC. Enter the
IP address assigned to the modulator followed by the number 26 – see below.
Figure 44: Starting the Telnet Session
A HyperTerminal session can also be used to access the CLI through the Ethernet port –
see Figure 43.
CLI Login Procedure
1. Once the connection has been established, press enter to get to the login prompt.
2. Enter the password and press enter. Note: The password is “admin” by default,
but can be changed through the Web GUI, CLI or SNMP.
3. After the password has been verified, the main menu will appear.
Figure 45: Telnet Login Prompt